ICD-10-PCS 2027 procedure code
00160JABypass Cerebral Ventricle to Subgaleal Space with Synthetic Substitute, Open Approach
Short description: Bypass Cereb Vent to Subgaleal with Synth Sub, Open Approach
Code last changed in FY2020 (effective October 1, 2019). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 00160JA
00160JA is the ICD-10-PCS code for a bypass procedure on the cerebral ventricle using an open approach with synthetic substitute (qualifier: subgaleal space). In ICD-10-PCS, bypass means altering the route of passage of the contents of a tubular body part.
The same procedure with a different approach is coded 00163JA (percutaneous) and 00164JA (percutaneous endoscopic).
With a different device, use 001607A (autologous tissue substitute) and 00160KA (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 023 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis with MCC or Antineoplastic Implant or Epilepsy with Neurostimulator), DRG 024 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis without MCC), DRG 025 (Craniotomy and Endovascular Intracranial Procedures with MCC), DRG 026 (Craniotomy and Endovascular Intracranial Procedures with CC), DRG 027 (Craniotomy and Endovascular Intracranial Procedures without CC/MCC) and DRG 820 (Lymphoma and Leukemia with Major O.R. Procedures with MCC), under the surgical categories “Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis”, “Craniotomy and endovascular intracranial procedures”, “Lymphoma and Leukemia with Major O.R. Procedures” and 3 more.
It was added in FY2020, effective October 1, 2019.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 0Central Nervous System and Cranial Nerves
- 3. Operation
- 1Bypass
Altering the route of passage of the contents of a tubular body part
Rerouting contents of a body part to a downstream area of the normal route, to a similar route and body part, or to an abnormal route and dissimilar body part. Includes one or more anastomoses, with or without the use of a device
Includes: Coronary artery bypass, colostomy formation
- 4. Body Part
- 6Cerebral Ventricle
Includes: Aqueduct of Sylvius; Cerebral aqueduct (Sylvius); Choroid plexus; Ependyma; Foramen of Monro (intraventricular); Fourth ventricle; Interventricular foramen (Monro); Left lateral ventricle; Right lateral ventricle; Third ventricle
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ASubgaleal Space
Other versions of this procedure
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy and endovascular intracranial procedures
MDC 17 · Myeloproliferative Diseases and Disorders, Poorly Differentiated Neoplasms · Lymphoma and Leukemia with Major O.R. Procedures
MDC 17 · Myeloproliferative Diseases and Disorders, Poorly Differentiated Neoplasms · Myeloproliferative Disorders or Poorly Differentiated Neoplasms with Major O.R. Procedures
- 826Myeloproliferative Disorders or Poorly Differentiated Neoplasms with Major O.R. Procedures with MCCRW 4.7581
- 827Myeloproliferative Disorders or Poorly Differentiated Neoplasms with Major O.R. Procedures with CCRW 2.3896
- 828Myeloproliferative Disorders or Poorly Differentiated Neoplasms with Major O.R. Procedures without CC/MCCRW 1.6955
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Craniotomy for Multiple Significant Trauma
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2020 (effective 10/1/2019): Added
- No changes since FY2020.
Common questions about 00160JA
Is 00160JA a valid ICD-10-PCS code for 2027?
- Yes. 00160JA is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 00160JA an O.R. procedure?
- Yes. 00160JA is an O.R. procedure in MS-DRG v44.0.
What DRG does 00160JA group to?
- Depending on the principal diagnosis, 00160JA can group to MS-DRG 023, MS-DRG 024, MS-DRG 025, MS-DRG 026, MS-DRG 027 and MS-DRG 820.