ICD-10-PCS 2027 procedure code
00H005ZInsertion of Radioactive Element, Palladium-103 Collagen Implant into Brain, Open Approach
Short description: Insertion of Pd-103 Colg Implt into Brain, Open Approach
Code last changed in FY2024 (effective October 1, 2023). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 00H005Z
00H005Z is the ICD-10-PCS code for a insertion procedure on the brain using an open approach with radioactive element, palladium-103 collagen implant. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.
With a different device, use 00H001Z (radioactive element), 00H002Z (monitoring device), 00H003Z (infusion device), 00H004Z (radioactive element, cesium-131 collagen implant), 00H00MZ (neurostimulator lead) and 00H00YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 023 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis with MCC or Antineoplastic Implant or Epilepsy with Neurostimulator), DRG 024 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis without MCC), DRG 025 (Craniotomy and Endovascular Intracranial Procedures with MCC), DRG 026 (Craniotomy and Endovascular Intracranial Procedures with CC), DRG 027 (Craniotomy and Endovascular Intracranial Procedures without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis”, “Craniotomy and endovascular intracranial procedures”, “Other O.R. Procedures for Injuries” and 1 more.
It was added in FY2024, effective October 1, 2023.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 0Central Nervous System and Cranial Nerves
- 3. Operation
- HInsertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Includes: Insertion of radioactive implant, insertion of central venous catheter
- 4. Body Part
- 0Brain
Includes: Cerebrum; Corpus callosum; Encephalon
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 5Radioactive Element, Palladium-103 Collagen Implant
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy and endovascular intracranial procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Craniotomy for Multiple Significant Trauma
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2024 (effective 10/1/2023): Added
- No changes since FY2024.
Common questions about 00H005Z
Is 00H005Z a valid ICD-10-PCS code for 2027?
- Yes. 00H005Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 00H005Z an O.R. procedure?
- Yes. 00H005Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 00H005Z group to?
- Depending on the principal diagnosis, 00H005Z can group to MS-DRG 023, MS-DRG 024, MS-DRG 025, MS-DRG 026, MS-DRG 027 and MS-DRG 907.