Skip to content
Dx

ICD-10-PCS 2027 procedure code

021P4JBBypass Pulmonary Trunk from Subclavian with Synthetic Substitute, Percutaneous Endoscopic Approach

✓ Valid for 2027O.R. procedure

Short description: Bypass Pulm Trunk from Subclav w Synth Sub, Perc Endo

Code last changed in FY2017 (effective October 1, 2016). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 021P4JB

021P4JB is the ICD-10-PCS code for a bypass procedure on the pulmonary trunk using a percutaneous endoscopic approach with synthetic substitute (qualifier: subclavian). In ICD-10-PCS, bypass means altering the route of passage of the contents of a tubular body part.

In plain terms, this corresponds to systemic to pulmonary artery shunt, the ICD-9-CM procedure title it maps to (39.0).

For a different body part, codes include 021Q4JB (right pulmonary artery), 021R4JB (left pulmonary artery), 021W4JB (thoracic aorta, descending) and 021X4JB (thoracic aorta, ascending/arch).

The same procedure with a different approach is coded 021P0JB (open).

With a different device, use 021P48B (zooplastic tissue), 021P49B (autologous venous tissue), 021P4AB (autologous arterial tissue), 021P4KB (nonautologous tissue substitute) and 021P4ZB (no device).

It is an operating-room procedure in the MS-DRG logic for DRG 166 (Other Respiratory System O.R. Procedures with MCC), DRG 167 (Other Respiratory System O.R. Procedures with CC), DRG 168 (Other Respiratory System O.R. Procedures without CC/MCC), DRG 252 (Other Vascular Procedures with MCC), DRG 253 (Other Vascular Procedures with CC) and DRG 254 (Other Vascular Procedures without CC/MCC), under the surgical categories “Other Respiratory System O.R. Procedures”, “Other Vascular Procedures”, “Other O.R. Procedures for Injuries” and 1 more.

It was added in FY2017, effective October 1, 2016.

What each character means

1. Section
0Medical and Surgical
2. Body System
2Heart and Great Vessels
3. Operation
1Bypass

Altering the route of passage of the contents of a tubular body part

Rerouting contents of a body part to a downstream area of the normal route, to a similar route and body part, or to an abnormal route and dissimilar body part. Includes one or more anastomoses, with or without the use of a device

Includes: Coronary artery bypass, colostomy formation

4. Body Part
PPulmonary Trunk
5. Approach
4Percutaneous Endoscopic

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
BSubclavian

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 39.0Systemic to pulmonary artery shuntapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2017 (effective 10/1/2016): Added
  • No changes since FY2017.

Common questions about 021P4JB

Is 021P4JB a valid ICD-10-PCS code for 2027?

Yes. 021P4JB is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 021P4JB an O.R. procedure?

Yes. 021P4JB is an O.R. procedure in MS-DRG v44.0.

What DRG does 021P4JB group to?

Depending on the principal diagnosis, 021P4JB can group to MS-DRG 166, MS-DRG 167, MS-DRG 168, MS-DRG 252, MS-DRG 253 and MS-DRG 254.

What is the ICD-9 procedure code for 021P4JB?

The CMS GEMs map 021P4JB to ICD-9-CM 39.0 (Systemic to pulmonary artery shunt).