Skip to content
Dx

ICD-10-PCS 2027 procedure code

024F0JJCreation of Aortic Valve from Truncal Valve using Synthetic Substitute, Open Approach

✓ Valid for 2027O.R. procedure

Short description: Create Aort Valve from Trunc Vlv w Synth Sub, Open

Code last changed in FY2017 (effective October 1, 2016). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 024F0JJ

024F0JJ is the ICD-10-PCS code for a creation procedure on the aortic valve using an open approach with synthetic substitute (qualifier: truncal valve). In ICD-10-PCS, creation means putting in or on biological or synthetic material to form a new body part that to the extent possible replicates the anatomic structure or function of an absent body part.

In plain terms, this corresponds to total repair of truncus arteriosus, the ICD-9-CM procedure title it maps to (35.83).

With a different device, use 024F07J (autologous tissue substitute), 024F08J (zooplastic tissue) and 024F0KJ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 212 (Concomitant Aortic and Mitral Valve Procedures), DRG 216 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCC), DRG 217 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CC), DRG 218 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCC), DRG 219 (Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCC) and DRG 220 (Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CC), under the surgical categories “Concomitant Aortic and Mitral Valve Procedures”, “” and “Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization”.

It was added in FY2017, effective October 1, 2016.

What each character means

1. Section
0Medical and Surgical
2. Body System
2Heart and Great Vessels
3. Operation
4Creation

Putting in or on biological or synthetic material to form a new body part that to the extent possible replicates the anatomic structure or function of an absent body part

Used for gender reassignment surgery and corrective procedures in individuals with congenital anomalies

Includes: Creation of vagina in a male, creation of right and left atrioventricular valve from common atrioventricular valve

4. Body Part
FAortic Valve

Includes: Aortic annulus

5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
JTruncal Valve

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 35.83Total repair of truncus arteriosusapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2017 (effective 10/1/2016): Added
  • No changes since FY2017.

Common questions about 024F0JJ

Is 024F0JJ a valid ICD-10-PCS code for 2027?

Yes. 024F0JJ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 024F0JJ an O.R. procedure?

Yes. 024F0JJ is an O.R. procedure in MS-DRG v44.0.

What DRG does 024F0JJ group to?

Depending on the principal diagnosis, 024F0JJ can group to MS-DRG 212, MS-DRG 216, MS-DRG 217, MS-DRG 218, MS-DRG 219 and MS-DRG 220.

What is the ICD-9 procedure code for 024F0JJ?

The CMS GEMs map 024F0JJ to ICD-9-CM 35.83 (Total repair of truncus arteriosus).