ICD-10-PCS 2027 procedure code
02HL0MZInsertion of Cardiac Lead into Left Ventricle, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02HL0MZ
02HL0MZ is the ICD-10-PCS code for a insertion procedure on the left ventricle using an open approach with cardiac lead. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.
In plain terms, this corresponds to initial insertion of lead [electrode], not otherwise specified, the ICD-9-CM procedure title it maps to (37.70).
For a different body part, codes include 02H40MZ (coronary vein), 02H60MZ (right atrium), 02H70MZ (left atrium), 02HK0MZ (right ventricle) and 02HN0MZ (pericardium).
The same procedure with a different approach is coded 02HL3MZ (percutaneous) and 02HL4MZ (percutaneous endoscopic).
With a different device, use 02HL00Z (monitoring device, pressure sensor), 02HL02Z (monitoring device), 02HL03Z (infusion device), 02HL0DZ (intraluminal device), 02HL0JZ (cardiac lead, pacemaker), 02HL0KZ (cardiac lead, defibrillator) and 2 more.
It is a non-O.R. procedure that is part of the MS-DRG logic for DRG 210 (Cardiac Pacemaker Revision or Device Replacement with MCC) and DRG 211 (Cardiac Pacemaker Revision or Device Replacement without MCC), under the surgical category “Cardiac Pacemaker Revision or Device Replacement”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- HInsertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Includes: Insertion of radioactive implant, insertion of central venous catheter
- 4. Body Part
- LVentricle, Left
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- MCardiac Lead
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Pacemaker Revision or Device Replacement
ICD-9-CM equivalent
Converter →- 37.70Initial insertion of lead [electrode], not otherwise specifiedapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 02HL0MZ
Is 02HL0MZ a valid ICD-10-PCS code for 2027?
- Yes. 02HL0MZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02HL0MZ an O.R. procedure?
- No. 02HL0MZ is designated non-O.R. in MS-DRG v44.0.
What DRG does 02HL0MZ group to?
- Depending on the principal diagnosis, 02HL0MZ can group to MS-DRG 210 and MS-DRG 211.
What is the ICD-9 procedure code for 02HL0MZ?
- The CMS GEMs map 02HL0MZ to ICD-9-CM 37.70 (Initial insertion of lead [electrode], not otherwise specified).