ICD-10-PCS 2027 procedure code
02RG4JZReplacement of Mitral Valve with Synthetic Substitute, Percutaneous Endoscopic Approach
Short description: Replace of Mitral Valve with Synth Sub, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02RG4JZ
02RG4JZ is the ICD-10-PCS code for a replacement procedure on the mitral valve using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.
In plain terms, this corresponds to open and other replacement of mitral valve, the ICD-9-CM procedure title it maps to (35.24).
For a different body part, codes include 02R54JZ (atrial septum), 02R64JZ (right atrium), 02R74JZ (left atrium), 02R94JZ (chordae tendineae), 02RD4JZ (papillary muscle), 02RF4JZ (aortic valve) and 14 more.
The same procedure with a different approach is coded 02RG0JZ (open) and 02RG3JZ (percutaneous).
With a different device, use 02RG47Z (autologous tissue substitute), 02RG48Z (zooplastic tissue) and 02RG4KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 212 (Concomitant Aortic and Mitral Valve Procedures), DRG 216 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCC), DRG 217 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CC), DRG 218 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCC), DRG 219 (Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCC) and DRG 220 (Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CC), under the surgical categories “Concomitant Aortic and Mitral Valve Procedures”, “” and “Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- RReplacement
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure
Includes: Total hip replacement, bone graft, free skin graft
- 4. Body Part
- GMitral Valve
Includes: Bicuspid valve; Left atrioventricular valve; Mitral annulus
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Concomitant Aortic and Mitral Valve Procedures
MDC 05 · Diseases and Disorders of the Circulatory System
- 216Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCCRW 9.8832
- 217Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CCRW 6.8061
- 218Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCCRW 6.8061
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization
- 219Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCCRW 7.6434
- 220Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CCRW 5.5066
- 221Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization without CC/MCCRW 4.7108
ICD-9-CM equivalent
Converter →- 35.24Open and other replacement of mitral valveapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 02RG4JZ
Is 02RG4JZ a valid ICD-10-PCS code for 2027?
- Yes. 02RG4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02RG4JZ an O.R. procedure?
- Yes. 02RG4JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 02RG4JZ group to?
- Depending on the principal diagnosis, 02RG4JZ can group to MS-DRG 212, MS-DRG 216, MS-DRG 217, MS-DRG 218, MS-DRG 219 and MS-DRG 220.
What is the ICD-9 procedure code for 02RG4JZ?
- The CMS GEMs map 02RG4JZ to ICD-9-CM 35.24 (Open and other replacement of mitral valve).