ICD-10-PCS 2027 procedure code
02UG0JZSupplement Mitral Valve with Synthetic Substitute, Open Approach
Short description: Supplement Mitral Valve with Synth Sub, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02UG0JZ
02UG0JZ is the ICD-10-PCS code for a supplement procedure on the mitral valve using an open approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to Annuloplasty and other operations on valves of heart, the ICD-9-CM procedure titles it maps to (35.33 and 35.99).
For a different body part, codes include 02U00JZ (coronary artery, one artery), 02U10JZ (coronary artery, two arteries), 02U20JZ (coronary artery, three arteries), 02U30JZ (coronary artery, four or more arteries), 02U50JZ (atrial septum), 02U60JZ (right atrium) and 19 more.
The same procedure with a different approach is coded 02UG3JZ (percutaneous) and 02UG4JZ (percutaneous endoscopic).
With a different device, use 02UG07Z (autologous tissue substitute), 02UG08Z (zooplastic tissue) and 02UG0KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 212 (Concomitant Aortic and Mitral Valve Procedures), DRG 216 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCC), DRG 217 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CC), DRG 218 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCC), DRG 219 (Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCC) and DRG 220 (Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CC), under the surgical categories “Concomitant Aortic and Mitral Valve Procedures”, “” and “Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- GMitral Valve
Includes: Bicuspid valve; Left atrioventricular valve; Mitral annulus
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 02U00JZCoronary Artery, One Artery
- 02U10JZCoronary Artery, Two Arteries
- 02U20JZCoronary Artery, Three Arteries
- 02U30JZCoronary Artery, Four or More Arteries
- 02U50JZAtrial Septum
- 02U60JZAtrium, Right
- 02U70JZAtrium, Left
- 02U90JZChordae Tendineae
- 02UA0JZHeart
- 02UD0JZPapillary Muscle
- 02UF0JZAortic Valve
- 02UH0JZPulmonary Valve
Different approach
Different device
Different qualifier
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Concomitant Aortic and Mitral Valve Procedures
MDC 05 · Diseases and Disorders of the Circulatory System
- 216Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCCRW 9.8832
- 217Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CCRW 6.8061
- 218Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCCRW 6.8061
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization
- 219Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCCRW 7.6434
- 220Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CCRW 5.5066
- 221Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization without CC/MCCRW 4.7108
ICD-9-CM equivalent
Converter →From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 02UG0JZ
Is 02UG0JZ a valid ICD-10-PCS code for 2027?
- Yes. 02UG0JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02UG0JZ an O.R. procedure?
- Yes. 02UG0JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 02UG0JZ group to?
- Depending on the principal diagnosis, 02UG0JZ can group to MS-DRG 212, MS-DRG 216, MS-DRG 217, MS-DRG 218, MS-DRG 219 and MS-DRG 220.
What is the ICD-9 procedure code for 02UG0JZ?
- The CMS GEMs map 02UG0JZ to ICD-9-CM 35.33 (Annuloplasty) and 35.99 (Other operations on valves of heart).