ICD-10-PCS 2027 procedure code
02UK4JZSupplement Right Ventricle with Synthetic Substitute, Percutaneous Endoscopic Approach
Short description: Supplement R Ventricle with Synth Sub, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02UK4JZ
02UK4JZ is the ICD-10-PCS code for a supplement procedure on the right ventricle using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to other repair of heart and pericardium, the ICD-9-CM procedure title it maps to (37.49).
For a different body part, codes include 02U04JZ (coronary artery, one artery), 02U14JZ (coronary artery, two arteries), 02U24JZ (coronary artery, three arteries), 02U34JZ (coronary artery, four or more arteries), 02U54JZ (atrial septum), 02U64JZ (right atrium) and 19 more.
The same procedure with a different approach is coded 02UK0JZ (open) and 02UK3JZ (percutaneous).
With a different device, use 02UK47Z (autologous tissue substitute), 02UK48Z (zooplastic tissue) and 02UK4KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 270 (Other Major Cardiovascular Procedures with MCC), DRG 271 (Other Major Cardiovascular Procedures with CC), DRG 272 (Other Major Cardiovascular Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Other Major Cardiovascular Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- KVentricle, Right
Includes: Conus arteriosus
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 02U04JZCoronary Artery, One Artery
- 02U14JZCoronary Artery, Two Arteries
- 02U24JZCoronary Artery, Three Arteries
- 02U34JZCoronary Artery, Four or More Arteries
- 02U54JZAtrial Septum
- 02U64JZAtrium, Right
- 02U74JZAtrium, Left
- 02U94JZChordae Tendineae
- 02UA4JZHeart
- 02UD4JZPapillary Muscle
- 02UF4JZAortic Valve
- 02UG4JZMitral Valve
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Major Cardiovascular Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 37.49Other repair of heart and pericardiumapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 02UK4JZ
Is 02UK4JZ a valid ICD-10-PCS code for 2027?
- Yes. 02UK4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02UK4JZ an O.R. procedure?
- Yes. 02UK4JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 02UK4JZ group to?
- Depending on the principal diagnosis, 02UK4JZ can group to MS-DRG 270, MS-DRG 271, MS-DRG 272, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 02UK4JZ?
- The CMS GEMs map 02UK4JZ to ICD-9-CM 37.49 (Other repair of heart and pericardium).