ICD-10-PCS 2027 procedure code
02WA0RZRevision of Short-term External Heart Assist System in Heart, Open Approach
Short description: Revision of Ext Heart Assist in Heart, Open Approach
Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02WA0RZ
02WA0RZ is the ICD-10-PCS code for a revision procedure on the heart using an open approach with short-term external heart assist system. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to repair of heart assist system, the ICD-9-CM procedure title it maps to (37.63).
The same procedure with a different approach is coded 02WA3RZ (percutaneous), 02WA4RZ (percutaneous endoscopic) and 02WAXRZ (external).
With a different device, use 02WA02Z (monitoring device), 02WA03Z (infusion device), 02WA07Z (autologous tissue substitute), 02WA08Z (zooplastic tissue), 02WA0CZ (extraluminal device), 02WA0DZ (intraluminal device) and 6 more.
It is an operating-room procedure in the MS-DRG logic for DRG 215 (Other Heart Assist System Implant), DRG 001 (Heart Transplant or Implant of Heart Assist System with MCC) and DRG 002 (Heart Transplant or Implant of Heart Assist System without MCC), under the surgical categories “Other Heart Assist System Implant” and “Heart Transplant or Implant of Heart Assist System”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- AHeart
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- RShort-term External Heart Assist System
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different approach
Different device
- 02WA02ZMonitoring Device
- 02WA03ZInfusion Device
- 02WA07ZAutologous Tissue Substitute
- 02WA08ZZooplastic Tissue
- 02WA0CZExtraluminal Device
- 02WA0DZIntraluminal Device
- 02WA0JZSynthetic Substitute
- 02WA0KZNonautologous Tissue Substitute
- 02WA0MZCardiac Lead
- 02WA0NZIntracardiac Pacemaker
- 02WA0QZImplantable Heart Assist System
- 02WA0YZOther Device
Different qualifier
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Heart Assist System Implant
MDC PRE · Pre-MDC · Heart Transplant or Implant of Heart Assist System
MDC PRE · Pre-MDC · Heart Transplant or Implant of Heart Assist System
MDC PRE · Pre-MDC · Heart Transplant or Implant of Heart Assist System
ICD-9-CM equivalent
Converter →- 37.63Repair of heart assist systemapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- FY2018 (effective 10/1/2017): Title revised — was “Revision of External Heart Assist System in Heart, Open Approach”
Common questions about 02WA0RZ
Is 02WA0RZ a valid ICD-10-PCS code for 2027?
- Yes. 02WA0RZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02WA0RZ an O.R. procedure?
- Yes. 02WA0RZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 02WA0RZ group to?
- Depending on the principal diagnosis, 02WA0RZ can group to MS-DRG 215, MS-DRG 001 and MS-DRG 002.
What is the ICD-9 procedure code for 02WA0RZ?
- The CMS GEMs map 02WA0RZ to ICD-9-CM 37.63 (Repair of heart assist system).