Skip to content
Dx

ICD-10-PCS 2027 procedure code

02WA32ZRevision of Monitoring Device in Heart, Percutaneous Approach

✓ Valid for 2027

Short description: Revision of Monitoring Device in Heart, Perc Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 02WA32Z

02WA32Z is the ICD-10-PCS code for a revision procedure on the heart using a percutaneous approach with monitoring device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Cardiotomy, the ICD-9-CM procedure title it maps to (37.11).

For a different body part, codes include 02WY32Z (great vessel).

The same procedure with a different approach is coded 02WA02Z (open), 02WA42Z (percutaneous endoscopic) and 02WAX2Z (external).

With a different device, use 02WA33Z (infusion device), 02WA37Z (autologous tissue substitute), 02WA38Z (zooplastic tissue), 02WA3CZ (extraluminal device), 02WA3DZ (intraluminal device), 02WA3JZ (synthetic substitute) and 6 more.

It doesn't appear in the MS-DRG procedure index, so on its own it doesn't change the DRG assignment.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
2Heart and Great Vessels
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
AHeart
5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
2Monitoring Device

Includes: Blood glucose monitoring system; Cardiac event recorder; Continuous Glucose Monitoring (CGM) device; Implantable glucose monitoring device; Loop recorder, implantable; Reveal (LINQ)(DX)(XT)

7. Qualifier
ZNo Qualifier

Other versions of this procedure

ICD-9-CM equivalent

Converter →
  • 37.11Cardiotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 02WA32Z

Is 02WA32Z a valid ICD-10-PCS code for 2027?

Yes. 02WA32Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

What is the ICD-9 procedure code for 02WA32Z?

The CMS GEMs map 02WA32Z to ICD-9-CM 37.11 (Cardiotomy).