ICD-10-PCS 2027 procedure code
02WA4DZRevision of Intraluminal Device in Heart, Percutaneous Endoscopic Approach
Short description: Revision of Intraluminal Device in Heart, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02WA4DZ
02WA4DZ is the ICD-10-PCS code for a revision procedure on the heart using a percutaneous endoscopic approach with intraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to Cardiotomy, the ICD-9-CM procedure title it maps to (37.11).
For a different body part, codes include 02WY4DZ (great vessel).
The same procedure with a different approach is coded 02WA0DZ (open), 02WA3DZ (percutaneous) and 02WAXDZ (external).
With a different device, use 02WA42Z (monitoring device), 02WA43Z (infusion device), 02WA47Z (autologous tissue substitute), 02WA48Z (zooplastic tissue), 02WA4CZ (extraluminal device), 02WA4JZ (synthetic substitute) and 6 more.
It is an operating-room procedure in the MS-DRG logic for DRG 228 (Other Cardiothoracic Procedures with MCC) and DRG 229 (Other Cardiothoracic Procedures without MCC), under the surgical category “Other Cardiothoracic Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- AHeart
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- DIntraluminal Device
Includes: Absolute Pro Vascular (OTW) Self-Expanding Stent System; Acculink (RX) Carotid Stent System; AFX(R) Endovascular AAA System; AneuRx(R) AAA Advantage(R); Assurant (Cobalt) stent; Carotid WALLSTENT(R) Monorail(R) Endoprosthesis; CoAxia NeuroFlo catheter; Colonic Z-Stent(R); Complete (SE) stent; Cook Zenith AAA Endovascular Graft; Driver stent (RX) (OTW); E-Luminexx(tm) (Biliary)(Vascular) Stent; Embolization coil(s); Endologix AFX(R) Endovascular AAA System; Endurant(R) Endovascular Stent Graft; Endurant(R) II AAA stent graft system; EXCLUDER(R) AAA Endoprosthesis; Express(R) (LD) Premounted Stent System; Express(R) Biliary SD Monorail(R) Premounted Stent System; Express(R) SD Renal Monorail(R) Premounted Stent System; FLAIR(R) Endovascular Stent Graft; Formula(tm) Balloon-Expandable Renal Stent System; GORE EXCLUDER(R) AAA Endoprosthesis; GORE TAG(R) Thoracic Endoprosthesis; GORE(R) VIABAHN(R) Endoprosthesis; GORE(R) VIABIL(R) Biliary Endoprosthesis; Herculink (RX) Elite Renal Stent System; Innova(tm) stent; LifeStent(R) (Flexstar)(XL) Vascular Stent System; Medtronic Endurant(R) II AAA stent graft system; Micro-Driver stent (RX) (OTW); MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System; Omnilink Elite Vascular Balloon Expandable Stent System; Protege(R) RX Carotid Stent System; Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary); Talent(R) Converter; Talent(R) Occluder; Talent(R) Stent Graft (abdominal)(thoracic); Therapeutic occlusion coil(s); Ultraflex(tm) Precision Colonic Stent System; Valiant Thoracic Stent Graft; WALLSTENT(R) Endoprosthesis; Xact Carotid Stent System; Zenith AAA Endovascular Graft; Zenith Flex(R) AAA Endovascular Graft; Zenith TX2(R) TAA Endovascular Graft; Zenith(R) Renu(tm) AAA Ancillary Graft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
Different device
- 02WA42ZMonitoring Device
- 02WA43ZInfusion Device
- 02WA47ZAutologous Tissue Substitute
- 02WA48ZZooplastic Tissue
- 02WA4CZExtraluminal Device
- 02WA4JZSynthetic Substitute
- 02WA4KZNonautologous Tissue Substitute
- 02WA4MZCardiac Lead
- 02WA4NZIntracardiac Pacemaker
- 02WA4QZImplantable Heart Assist System
- 02WA4RZShort-term External Heart Assist System
- 02WA4YZOther Device
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Cardiothoracic Procedures
ICD-9-CM equivalent
Converter →- 37.11Cardiotomyapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 02WA4DZ
Is 02WA4DZ a valid ICD-10-PCS code for 2027?
- Yes. 02WA4DZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02WA4DZ an O.R. procedure?
- Yes. 02WA4DZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 02WA4DZ group to?
- Depending on the principal diagnosis, 02WA4DZ can group to MS-DRG 228 and MS-DRG 229.
What is the ICD-9 procedure code for 02WA4DZ?
- The CMS GEMs map 02WA4DZ to ICD-9-CM 37.11 (Cardiotomy).