Skip to content
Dx

ICD-10-PCS 2027 procedure code

02WJ37ZRevision of Autologous Tissue Substitute in Tricuspid Valve, Percutaneous Approach

✓ Valid for 2027O.R. procedure

Short description: Revision of Autol Sub in Tricusp Valve, Perc Approach

Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 02WJ37Z

02WJ37Z is the ICD-10-PCS code for a revision procedure on the tricuspid valve using a percutaneous approach with autologous tissue substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to revision of corrective procedure on heart, the ICD-9-CM procedure title it maps to (35.95).

For a different body part, codes include 02WA37Z (heart), 02WF37Z (aortic valve), 02WG37Z (mitral valve), 02WH37Z (pulmonary valve) and 02WY37Z (great vessel).

The same procedure with a different approach is coded 02WJ07Z (open) and 02WJ47Z (percutaneous endoscopic).

With a different device, use 02WJ38Z (zooplastic tissue), 02WJ3JZ (synthetic substitute) and 02WJ3KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 319 (Other Endovascular Cardiac Valve Procedures with MCC) and DRG 320 (Other Endovascular Cardiac Valve Procedures without MCC), under the surgical category “Other Endovascular Cardiac Valve Procedures”.

It was added in FY2018, effective October 1, 2017.

What each character means

1. Section
0Medical and Surgical
2. Body System
2Heart and Great Vessels
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
JTricuspid Valve

Includes: Right atrioventricular valve; Tricuspid annulus

5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
7Autologous Tissue Substitute

Includes: Autograft; Cultured epidermal cell autograft; Epicel(R) cultured epidermal autograft

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 05 · Diseases and Disorders of the Circulatory System · Other Endovascular Cardiac Valve Procedures

ICD-9-CM equivalent

Converter →
  • 35.95Revision of corrective procedure on heartapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2018 (effective 10/1/2017): Added
  • No changes since FY2018.

Common questions about 02WJ37Z

Is 02WJ37Z a valid ICD-10-PCS code for 2027?

Yes. 02WJ37Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 02WJ37Z an O.R. procedure?

Yes. 02WJ37Z is an O.R. procedure in MS-DRG v44.0.

What DRG does 02WJ37Z group to?

Depending on the principal diagnosis, 02WJ37Z can group to MS-DRG 319 and MS-DRG 320.

What is the ICD-9 procedure code for 02WJ37Z?

The CMS GEMs map 02WJ37Z to ICD-9-CM 35.95 (Revision of corrective procedure on heart).