ICD-10-PCS 2027 procedure code
03R00KZReplacement of Right Internal Mammary Artery with Nonautologous Tissue Substitute, Open Approach
Short description: Replacement of R Int Mamm Art with Nonaut Sub, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 03R00KZ
03R00KZ is the ICD-10-PCS code for a replacement procedure on the right internal mammary artery using an open approach with nonautologous tissue substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.
In plain terms, this corresponds to resection of vessel with replacement, thoracic vessels, the ICD-9-CM procedure title it maps to (38.45).
For a different body part, codes include 03R10KZ (left internal mammary artery), 03R20KZ (innominate artery), 03R30KZ (right subclavian artery), 03R40KZ (left subclavian artery), 03R50KZ (right axillary artery), 03R60KZ (left axillary artery) and 23 more.
The same procedure with a different approach is coded 03R04KZ (percutaneous endoscopic).
With a different device, use 03R007Z (autologous tissue substitute) and 03R00JZ (synthetic substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 163 (Major Chest Procedures with MCC), DRG 164 (Major Chest Procedures with CC), DRG 165 (Major Chest Procedures without CC/MCC), DRG 212 (Concomitant Aortic and Mitral Valve Procedures), DRG 216 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCC) and DRG 217 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CC), under the surgical categories “Major Chest Procedures”, “Concomitant Aortic and Mitral Valve Procedures”, “” and 3 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 3Upper Arteries
- 3. Operation
- RReplacement
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure
Includes: Total hip replacement, bone graft, free skin graft
- 4. Body Part
- 0Internal Mammary Artery, Right
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- KNonautologous Tissue Substitute
Includes: Acellular Hydrated Dermis; Bone bank bone graft; Cook Biodesign(R) Fistula Plug(s); Cook Biodesign(R) Hernia Graft(s); Cook Biodesign(R) Layered Graft(s); Cook Zenapro(tm) Layered Graft(s); Fish skin; Kerecis(R) (GraftGuide) (MariGen) (SurgiBind) (SurgiClose); MIRODERM(tm) Biologic Wound Matrix; Piscine skin; Tissue bank graft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 03R10KZInternal Mammary Artery, Left
- 03R20KZInnominate Artery
- 03R30KZSubclavian Artery, Right
- 03R40KZSubclavian Artery, Left
- 03R50KZAxillary Artery, Right
- 03R60KZAxillary Artery, Left
- 03R70KZBrachial Artery, Right
- 03R80KZBrachial Artery, Left
- 03R90KZUlnar Artery, Right
- 03RA0KZUlnar Artery, Left
- 03RB0KZRadial Artery, Right
- 03RC0KZRadial Artery, Left
Different approach
Different device
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 04 · Diseases and Disorders of the Respiratory System · Major Chest Procedures
MDC 05 · Diseases and Disorders of the Circulatory System · Concomitant Aortic and Mitral Valve Procedures
MDC 05 · Diseases and Disorders of the Circulatory System
- 216Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCCRW 9.8832
- 217Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CCRW 6.8061
- 218Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCCRW 6.8061
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization
- 219Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCCRW 7.6434
- 220Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CCRW 5.5066
- 221Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization without CC/MCCRW 4.7108
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 38.45Resection of vessel with replacement, thoracic vesselsapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 03R00KZ
Is 03R00KZ a valid ICD-10-PCS code for 2027?
- Yes. 03R00KZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 03R00KZ an O.R. procedure?
- Yes. 03R00KZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 03R00KZ group to?
- Depending on the principal diagnosis, 03R00KZ can group to MS-DRG 163, MS-DRG 164, MS-DRG 165, MS-DRG 212, MS-DRG 216 and MS-DRG 217.
What is the ICD-9 procedure code for 03R00KZ?
- The CMS GEMs map 03R00KZ to ICD-9-CM 38.45 (Resection of vessel with replacement, thoracic vessels).