ICD-10-PCS 2027 procedure code
03R40JZReplacement of Left Subclavian Artery with Synthetic Substitute, Open Approach
Short description: Replacement of L Subclav Art with Synth Sub, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 03R40JZ
03R40JZ is the ICD-10-PCS code for a replacement procedure on the left subclavian artery using an open approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.
In plain terms, this corresponds to resection of vessel with replacement, thoracic vessels, the ICD-9-CM procedure title it maps to (38.45).
For a different body part, codes include 03R00JZ (right internal mammary artery), 03R10JZ (left internal mammary artery), 03R20JZ (innominate artery), 03R30JZ (right subclavian artery), 03R50JZ (right axillary artery), 03R60JZ (left axillary artery) and 23 more.
The same procedure with a different approach is coded 03R44JZ (percutaneous endoscopic).
With a different device, use 03R407Z (autologous tissue substitute) and 03R40KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 163 (Major Chest Procedures with MCC), DRG 164 (Major Chest Procedures with CC), DRG 165 (Major Chest Procedures without CC/MCC), DRG 212 (Concomitant Aortic and Mitral Valve Procedures), DRG 216 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCC) and DRG 217 (Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CC), under the surgical categories “Major Chest Procedures”, “Concomitant Aortic and Mitral Valve Procedures”, “” and 3 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 3Upper Arteries
- 3. Operation
- RReplacement
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure
Includes: Total hip replacement, bone graft, free skin graft
- 4. Body Part
- 4Subclavian Artery, Left
Includes: Costocervical trunk; Dorsal scapular artery; Internal thoracic artery
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 03R00JZInternal Mammary Artery, Right
- 03R10JZInternal Mammary Artery, Left
- 03R20JZInnominate Artery
- 03R30JZSubclavian Artery, Right
- 03R50JZAxillary Artery, Right
- 03R60JZAxillary Artery, Left
- 03R70JZBrachial Artery, Right
- 03R80JZBrachial Artery, Left
- 03R90JZUlnar Artery, Right
- 03RA0JZUlnar Artery, Left
- 03RB0JZRadial Artery, Right
- 03RC0JZRadial Artery, Left
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 04 · Diseases and Disorders of the Respiratory System · Major Chest Procedures
MDC 05 · Diseases and Disorders of the Circulatory System · Concomitant Aortic and Mitral Valve Procedures
MDC 05 · Diseases and Disorders of the Circulatory System
- 216Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCCRW 9.8832
- 217Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CCRW 6.8061
- 218Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCCRW 6.8061
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization
- 219Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with MCCRW 7.6434
- 220Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization with CCRW 5.5066
- 221Cardiac Valve and Other Major Cardiothoracic Procedures without Cardiac Catheterization without CC/MCCRW 4.7108
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 38.45Resection of vessel with replacement, thoracic vesselsapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 03R40JZ
Is 03R40JZ a valid ICD-10-PCS code for 2027?
- Yes. 03R40JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 03R40JZ an O.R. procedure?
- Yes. 03R40JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 03R40JZ group to?
- Depending on the principal diagnosis, 03R40JZ can group to MS-DRG 163, MS-DRG 164, MS-DRG 165, MS-DRG 212, MS-DRG 216 and MS-DRG 217.
What is the ICD-9 procedure code for 03R40JZ?
- The CMS GEMs map 03R40JZ to ICD-9-CM 38.45 (Resection of vessel with replacement, thoracic vessels).