ICD-10-PCS 2027 procedure code
04104J2Bypass Abdominal Aorta to Mesenteric Artery with Synthetic Substitute, Percutaneous Endoscopic Approach
Short description: Bypass Abd Aorta to Mesent Art w Synth Sub, Perc Endo
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 04104J2
04104J2 is the ICD-10-PCS code for a bypass procedure on the abdominal aorta using a percutaneous endoscopic approach with synthetic substitute (qualifier: mesenteric artery). In ICD-10-PCS, bypass means altering the route of passage of the contents of a tubular body part.
In plain terms, this corresponds to other intra-abdominal vascular shunt or bypass, the ICD-9-CM procedure title it maps to (39.26).
For a different body part, codes include 041C4J2 (right common iliac artery) and 041D4J2 (left common iliac artery).
The same procedure with a different approach is coded 04100J2 (open).
With a different device, use 0410492 (autologous venous tissue), 04104A2 (autologous arterial tissue), 04104K2 (nonautologous tissue substitute) and 04104Z2 (no device).
It is an operating-room procedure in the MS-DRG logic for DRG 270 (Other Major Cardiovascular Procedures with MCC), DRG 271 (Other Major Cardiovascular Procedures with CC) and DRG 272 (Other Major Cardiovascular Procedures without CC/MCC), under the surgical category “Other Major Cardiovascular Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 4Lower Arteries
- 3. Operation
- 1Bypass
Altering the route of passage of the contents of a tubular body part
Rerouting contents of a body part to a downstream area of the normal route, to a similar route and body part, or to an abnormal route and dissimilar body part. Includes one or more anastomoses, with or without the use of a device
Includes: Coronary artery bypass, colostomy formation
- 4. Body Part
- 0Abdominal Aorta
Includes: Inferior phrenic artery; Lumbar artery; Median sacral artery; Middle suprarenal artery; Ovarian artery; Testicular artery
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- 2Mesenteric Artery
Other versions of this procedure
Different body part
Different approach
Different device
Different qualifier
- 04104J0Abdominal Aorta
- 04104J1Celiac Artery
- 04104J3Renal Artery, Right
- 04104J4Renal Artery, Left
- 04104J5Renal Artery, Bilateral
- 04104J6Common Iliac Artery, Right
- 04104J7Common Iliac Artery, Left
- 04104J8Common Iliac Arteries, Bilateral
- 04104J9Internal Iliac Artery, Right
- 04104JBInternal Iliac Artery, Left
- 04104JCInternal Iliac Arteries, Bilateral
- 04104JDExternal Iliac Artery, Right
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Major Cardiovascular Procedures
ICD-9-CM equivalent
Converter →- 39.26Other intra-abdominal vascular shunt or bypassapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 04104J2
Is 04104J2 a valid ICD-10-PCS code for 2027?
- Yes. 04104J2 is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 04104J2 an O.R. procedure?
- Yes. 04104J2 is an O.R. procedure in MS-DRG v44.0.
What DRG does 04104J2 group to?
- Depending on the principal diagnosis, 04104J2 can group to MS-DRG 270, MS-DRG 271 and MS-DRG 272.
What is the ICD-9 procedure code for 04104J2?
- The CMS GEMs map 04104J2 to ICD-9-CM 39.26 (Other intra-abdominal vascular shunt or bypass).