ICD-10-PCS 2027 procedure code
04R44JZReplacement of Splenic Artery with Synthetic Substitute, Percutaneous Endoscopic Approach
Short description: Replace of Splenic Art with Synth Sub, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 04R44JZ
04R44JZ is the ICD-10-PCS code for a replacement procedure on the splenic artery using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.
In plain terms, this corresponds to resection of vessel with replacement, abdominal arteries, the ICD-9-CM procedure title it maps to (38.46).
For a different body part, codes include 04R04JZ (abdominal aorta), 04R14JZ (celiac artery), 04R24JZ (gastric artery), 04R34JZ (hepatic artery), 04R54JZ (superior mesenteric artery), 04R64JZ (right colic artery) and 24 more.
The same procedure with a different approach is coded 04R40JZ (open).
With a different device, use 04R447Z (autologous tissue substitute) and 04R44KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 270 (Other Major Cardiovascular Procedures with MCC), DRG 271 (Other Major Cardiovascular Procedures with CC), DRG 272 (Other Major Cardiovascular Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Other Major Cardiovascular Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 4Lower Arteries
- 3. Operation
- RReplacement
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure
Includes: Total hip replacement, bone graft, free skin graft
- 4. Body Part
- 4Splenic Artery
Includes: Left gastroepiploic artery; Pancreatic artery; Short gastric artery
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 04R04JZAbdominal Aorta
- 04R14JZCeliac Artery
- 04R24JZGastric Artery
- 04R34JZHepatic Artery
- 04R54JZSuperior Mesenteric Artery
- 04R64JZColic Artery, Right
- 04R74JZColic Artery, Left
- 04R84JZColic Artery, Middle
- 04R94JZRenal Artery, Right
- 04RA4JZRenal Artery, Left
- 04RB4JZInferior Mesenteric Artery
- 04RC4JZCommon Iliac Artery, Right
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Major Cardiovascular Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 38.46Resection of vessel with replacement, abdominal arteriesapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 04R44JZ
Is 04R44JZ a valid ICD-10-PCS code for 2027?
- Yes. 04R44JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 04R44JZ an O.R. procedure?
- Yes. 04R44JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 04R44JZ group to?
- Depending on the principal diagnosis, 04R44JZ can group to MS-DRG 270, MS-DRG 271, MS-DRG 272, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 04R44JZ?
- The CMS GEMs map 04R44JZ to ICD-9-CM 38.46 (Resection of vessel with replacement, abdominal arteries).