ICD-10-PCS 2027 procedure code
06WY02ZRevision of Monitoring Device in Lower Vein, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 06WY02Z
06WY02Z is the ICD-10-PCS code for a revision procedure on the lower vein using an open approach with monitoring device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to incision of vessel, lower limb veins, the ICD-9-CM procedure title it maps to (38.09).
The same procedure with a different approach is coded 06WY32Z (percutaneous), 06WY42Z (percutaneous endoscopic) and 06WYX2Z (external).
With a different device, use 06WY00Z (drainage device), 06WY03Z (infusion device), 06WY07Z (autologous tissue substitute), 06WY0CZ (extraluminal device), 06WY0DZ (intraluminal device), 06WY0JZ (synthetic substitute) and 2 more.
It is an operating-room procedure in the MS-DRG logic for DRG 263 (Vein Ligation and Stripping), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC), DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), DRG 957 (Other O.R. Procedures for Multiple Significant Trauma with MCC) and DRG 958 (Other O.R. Procedures for Multiple Significant Trauma with CC), under the surgical categories “Vein Ligation and Stripping”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 6Lower Veins
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- YLower Vein
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 2Monitoring Device
Includes: Blood glucose monitoring system; Cardiac event recorder; Continuous Glucose Monitoring (CGM) device; Implantable glucose monitoring device; Loop recorder, implantable; Reveal (LINQ)(DX)(XT)
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Vein Ligation and Stripping
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 38.09Incision of vessel, lower limb veinsapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 06WY02Z
Is 06WY02Z a valid ICD-10-PCS code for 2027?
- Yes. 06WY02Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 06WY02Z an O.R. procedure?
- Yes. 06WY02Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 06WY02Z group to?
- Depending on the principal diagnosis, 06WY02Z can group to MS-DRG 263, MS-DRG 907, MS-DRG 908, MS-DRG 909, MS-DRG 957 and MS-DRG 958.
What is the ICD-9 procedure code for 06WY02Z?
- The CMS GEMs map 06WY02Z to ICD-9-CM 38.09 (Incision of vessel, lower limb veins).