ICD-10-PCS 2027 procedure code
08UE37ZSupplement Right Retina with Autologous Tissue Substitute, Percutaneous Approach
Short description: Supplement Right Retina with Autol Sub, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 08UE37Z
08UE37Z is the ICD-10-PCS code for a supplement procedure on the right retina using a percutaneous approach with autologous tissue substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to other repair of retinal tear, the ICD-9-CM procedure title it maps to (14.39).
For a different body part, codes include 08U037Z (right eye), 08U137Z (left eye), 08U837Z (right cornea), 08U937Z (left cornea), 08UC37Z (right iris), 08UD37Z (left iris) and 11 more.
The same procedure with a different approach is coded 08UE07Z (open).
With a different device, use 08UE3JZ (synthetic substitute) and 08UE3KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 116 (Intraocular Procedures with CC/MCC) and DRG 117 (Intraocular Procedures without CC/MCC), under the surgical category “Intraocular Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 8Eye
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- ERetina, Right
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 7Autologous Tissue Substitute
Includes: Autograft; Cultured epidermal cell autograft; Epicel(R) cultured epidermal autograft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 02 · Diseases and Disorders of the Eye · Intraocular Procedures
ICD-9-CM equivalent
Converter →- 14.39Other repair of retinal tearapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 08UE37Z
Is 08UE37Z a valid ICD-10-PCS code for 2027?
- Yes. 08UE37Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 08UE37Z an O.R. procedure?
- Yes. 08UE37Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 08UE37Z group to?
- Depending on the principal diagnosis, 08UE37Z can group to MS-DRG 116 and MS-DRG 117.
What is the ICD-9 procedure code for 08UE37Z?
- The CMS GEMs map 08UE37Z to ICD-9-CM 14.39 (Other repair of retinal tear).