08W00JZ is the ICD-10-PCS code for a revision procedure on the right eye using an open approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to revision or replacement of epiretinal visual prosthesis and revision and reinsertion of ocular implant, the ICD-9-CM procedure titles it maps to (14.83 and 16.62).

For a different body part, codes include 08W10JZ (left eye), 08WL0JZ (right extraocular muscle) and 08WM0JZ (left extraocular muscle).

The same procedure with a different approach is coded 08W03JZ (percutaneous), 08W07JZ (via natural or artificial opening), 08W08JZ (via natural or artificial opening endoscopic) and 08W0XJZ (external).

With a different device, use 08W000Z (drainage device), 08W003Z (infusion device), 08W007Z (autologous tissue substitute), 08W00CZ (extraluminal device), 08W00DZ (intraluminal device), 08W00KZ (nonautologous tissue substitute) and 1 more.

It is an operating-room procedure in the MS-DRG logic for DRG 113 (Orbital Procedures with CC/MCC), DRG 114 (Orbital Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC), DRG 909 (Other O.R. Procedures for Injuries without CC/MCC) and DRG 957 (Other O.R. Procedures for Multiple Significant Trauma with MCC), under the surgical categories “Orbital Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
8Eye
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
0Eye, Right
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 14.83Revision or replacement of epiretinal visual prosthesisapproximate
  • 16.62Revision and reinsertion of ocular implantapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 08W00JZ

Is 08W00JZ a valid ICD-10-PCS code for 2027?

Yes. 08W00JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 08W00JZ an O.R. procedure?

Yes. 08W00JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 08W00JZ group to?

Depending on the principal diagnosis, 08W00JZ can group to MS-DRG 113, MS-DRG 114, MS-DRG 907, MS-DRG 908, MS-DRG 909 and MS-DRG 957.

What is the ICD-9 procedure code for 08W00JZ?

The CMS GEMs map 08W00JZ to ICD-9-CM 14.83 (Revision or replacement of epiretinal visual prosthesis) and 16.62 (Revision and reinsertion of ocular implant).