Skip to content
Dx

ICD-10-PCS 2027 procedure code

08W13JZRevision of Synthetic Substitute in Left Eye, Percutaneous Approach

✓ Valid for 2027O.R. procedure

Short description: Revision of Synthetic Substitute in Left Eye, Perc Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 08W13JZ

08W13JZ is the ICD-10-PCS code for a revision procedure on the left eye using a percutaneous approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to revision or replacement of epiretinal visual prosthesis and revision and reinsertion of ocular implant, the ICD-9-CM procedure titles it maps to (14.83 and 16.62).

For a different body part, codes include 08W03JZ (right eye), 08WJ3JZ (right lens), 08WK3JZ (left lens), 08WL3JZ (right extraocular muscle) and 08WM3JZ (left extraocular muscle).

The same procedure with a different approach is coded 08W10JZ (open), 08W17JZ (via natural or artificial opening), 08W18JZ (via natural or artificial opening endoscopic) and 08W1XJZ (external).

With a different device, use 08W130Z (drainage device), 08W133Z (infusion device), 08W137Z (autologous tissue substitute), 08W13CZ (extraluminal device), 08W13DZ (intraluminal device), 08W13KZ (nonautologous tissue substitute) and 1 more.

It is an operating-room procedure in the MS-DRG logic for DRG 113 (Orbital Procedures with CC/MCC), DRG 114 (Orbital Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC), DRG 909 (Other O.R. Procedures for Injuries without CC/MCC) and DRG 957 (Other O.R. Procedures for Multiple Significant Trauma with MCC), under the surgical categories “Orbital Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
8Eye
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
1Eye, Left

Includes: Ciliary body; Posterior chamber

5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 14.83Revision or replacement of epiretinal visual prosthesisapproximate
  • 16.62Revision and reinsertion of ocular implantapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 08W13JZ

Is 08W13JZ a valid ICD-10-PCS code for 2027?

Yes. 08W13JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 08W13JZ an O.R. procedure?

Yes. 08W13JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 08W13JZ group to?

Depending on the principal diagnosis, 08W13JZ can group to MS-DRG 113, MS-DRG 114, MS-DRG 907, MS-DRG 908, MS-DRG 909 and MS-DRG 957.

What is the ICD-9 procedure code for 08W13JZ?

The CMS GEMs map 08W13JZ to ICD-9-CM 14.83 (Revision or replacement of epiretinal visual prosthesis) and 16.62 (Revision and reinsertion of ocular implant).