Skip to content
Dx

ICD-10-PCS 2027 procedure code

09RN8JZReplacement of Nasopharynx with Synthetic Substitute, Via Natural or Artificial Opening Endoscopic

✓ Valid for 2027O.R. procedure

Short description: Replacement of Nasopharynx with Synthetic Substitute, Endo

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 09RN8JZ

09RN8JZ is the ICD-10-PCS code for a replacement procedure on the nasopharynx using a via natural or artificial opening endoscopic approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.

In plain terms, this corresponds to plastic operation on pharynx, the ICD-9-CM procedure title it maps to (29.4).

For a different body part, codes include 09R78JZ (right tympanic membrane), 09R88JZ (left tympanic membrane) and 09RL8JZ (nasal turbinate).

The same procedure with a different approach is coded 09RN0JZ (open) and 09RN7JZ (via natural or artificial opening).

With a different device, use 09RN87Z (autologous tissue substitute) and 09RN8KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 040 (Peripheral, Cranial Nerve and Other Nervous System Procedures with MCC), DRG 041 (Peripheral, Cranial Nerve and Other Nervous System Procedures with CC or Peripheral Neurostimulator), DRG 042 (Peripheral, Cranial Nerve and Other Nervous System Procedures without CC/MCC), DRG 143 (Other Ear, Nose, Mouth and Throat O.R. Procedures with MCC), DRG 144 (Other Ear, Nose, Mouth and Throat O.R. Procedures with CC) and DRG 145 (Other Ear, Nose, Mouth and Throat O.R. Procedures without CC/MCC), under the surgical categories “Peripheral, Cranial Nerve and Other Nervous System Procedures”, “Other Ear, Nose, Mouth and Throat O.R. Procedures”, “Other O.R. Procedures for Injuries” and 1 more.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
9Ear, Nose, Sinus
3. Operation
RReplacement

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure

Includes: Total hip replacement, bone graft, free skin graft

4. Body Part
NNasopharynx

Includes: Choana; Fossa of Rosenmuller; Pharyngeal recess; Rhinopharynx

5. Approach
8Via Natural or Artificial Opening Endoscopic

Entry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 29.4Plastic operation on pharynxapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 09RN8JZ

Is 09RN8JZ a valid ICD-10-PCS code for 2027?

Yes. 09RN8JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 09RN8JZ an O.R. procedure?

Yes. 09RN8JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 09RN8JZ group to?

Depending on the principal diagnosis, 09RN8JZ can group to MS-DRG 040, MS-DRG 041, MS-DRG 042, MS-DRG 143, MS-DRG 144 and MS-DRG 145.

What is the ICD-9 procedure code for 09RN8JZ?

The CMS GEMs map 09RN8JZ to ICD-9-CM 29.4 (Plastic operation on pharynx).