ICD-10-PCS 2027 procedure code
09UD0JZSupplement Right Inner Ear with Synthetic Substitute, Open Approach
Short description: Supplement Right Inner Ear with Synth Sub, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 09UD0JZ
09UD0JZ is the ICD-10-PCS code for a supplement procedure on the right inner ear using an open approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to other operations on middle and inner ear, the ICD-9-CM procedure title it maps to (20.99).
For a different body part, codes include 09U00JZ (right external ear), 09U10JZ (left external ear), 09U20JZ (bilateral external ear), 09U50JZ (right middle ear), 09U60JZ (left middle ear), 09U70JZ (right tympanic membrane) and 19 more.
The same procedure with a different approach is coded 09UD8JZ (via natural or artificial opening endoscopic).
With a different device, use 09UD07Z (autologous tissue substitute) and 09UD0KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 143 (Other Ear, Nose, Mouth and Throat O.R. Procedures with MCC), DRG 144 (Other Ear, Nose, Mouth and Throat O.R. Procedures with CC) and DRG 145 (Other Ear, Nose, Mouth and Throat O.R. Procedures without CC/MCC), under the surgical category “Other Ear, Nose, Mouth and Throat O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 9Ear, Nose, Sinus
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- DInner Ear, Right
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 09U00JZExternal Ear, Right
- 09U10JZExternal Ear, Left
- 09U20JZExternal Ear, Bilateral
- 09U50JZMiddle Ear, Right
- 09U60JZMiddle Ear, Left
- 09U70JZTympanic Membrane, Right
- 09U80JZTympanic Membrane, Left
- 09U90JZAuditory Ossicle, Right
- 09UA0JZAuditory Ossicle, Left
- 09UB0JZMastoid Sinus, Right
- 09UC0JZMastoid Sinus, Left
- 09UE0JZInner Ear, Left
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 03 · Diseases and Disorders of the Ear, Nose, Mouth and Throat · Other Ear, Nose, Mouth and Throat O.R. Procedures
ICD-9-CM equivalent
Converter →- 20.99Other operations on middle and inner earapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 09UD0JZ
Is 09UD0JZ a valid ICD-10-PCS code for 2027?
- Yes. 09UD0JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 09UD0JZ an O.R. procedure?
- Yes. 09UD0JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 09UD0JZ group to?
- Depending on the principal diagnosis, 09UD0JZ can group to MS-DRG 143, MS-DRG 144 and MS-DRG 145.
What is the ICD-9 procedure code for 09UD0JZ?
- The CMS GEMs map 09UD0JZ to ICD-9-CM 20.99 (Other operations on middle and inner ear).