ICD-10-PCS 2027 procedure code
0BW033ZRevision of Infusion Device in Tracheobronchial Tree, Percutaneous Approach
Short description: Revision of Infusion Dev in Tracheobronc Tree, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0BW033Z
0BW033Z is the ICD-10-PCS code for a revision procedure on the tracheobronchial tree using a percutaneous approach with infusion device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of larynx or trachea, the ICD-9-CM procedure title it maps to (31.3).
For a different body part, codes include 0BWK33Z (right lung) and 0BWL33Z (left lung).
The same procedure with a different approach is coded 0BW003Z (open), 0BW043Z (percutaneous endoscopic), 0BW073Z (via natural or artificial opening), 0BW083Z (via natural or artificial opening endoscopic) and 0BW0X3Z (external).
With a different device, use 0BW030Z (drainage device), 0BW032Z (monitoring device), 0BW037Z (autologous tissue substitute), 0BW03CZ (extraluminal device), 0BW03DZ (intraluminal device), 0BW03JZ (synthetic substitute) and 2 more.
It is an operating-room procedure in the MS-DRG logic for DRG 166 (Other Respiratory System O.R. Procedures with MCC), DRG 167 (Other Respiratory System O.R. Procedures with CC) and DRG 168 (Other Respiratory System O.R. Procedures without CC/MCC), under the surgical category “Other Respiratory System O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- BRespiratory System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 0Tracheobronchial Tree
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 3Infusion Device
Includes: Ascenda Intrathecal Catheter; InDura, intrathecal catheter (1P) (spinal); Non-tunneled central venous catheter; Peripherally inserted central catheter (PICC); Tunneled spinal (intrathecal) catheter
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 04 · Diseases and Disorders of the Respiratory System · Other Respiratory System O.R. Procedures
ICD-9-CM equivalent
Converter →- 31.3Other incision of larynx or tracheaapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0BW033Z
Is 0BW033Z a valid ICD-10-PCS code for 2027?
- Yes. 0BW033Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0BW033Z an O.R. procedure?
- Yes. 0BW033Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0BW033Z group to?
- Depending on the principal diagnosis, 0BW033Z can group to MS-DRG 166, MS-DRG 167 and MS-DRG 168.
What is the ICD-9 procedure code for 0BW033Z?
- The CMS GEMs map 0BW033Z to ICD-9-CM 31.3 (Other incision of larynx or trachea).