ICD-10-PCS 2027 procedure code
0BW17CZRevision of Extraluminal Device in Trachea, Via Natural or Artificial Opening
Short description: Revision of Extraluminal Device in Trachea, Via Opening
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0BW17CZ
0BW17CZ is the ICD-10-PCS code for a revision procedure on the trachea using a via natural or artificial opening approach with extraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of larynx or trachea, the ICD-9-CM procedure title it maps to (31.3).
For a different body part, codes include 0BW07CZ (tracheobronchial tree).
The same procedure with a different approach is coded 0BW10CZ (open), 0BW13CZ (percutaneous), 0BW14CZ (percutaneous endoscopic), 0BW18CZ (via natural or artificial opening endoscopic) and 0BW1XCZ (external).
With a different device, use 0BW170Z (drainage device), 0BW172Z (monitoring device), 0BW177Z (autologous tissue substitute), 0BW17DZ (intraluminal device), 0BW17FZ (tracheostomy device), 0BW17JZ (synthetic substitute) and 1 more.
It is an operating-room procedure in the MS-DRG logic for DRG 166 (Other Respiratory System O.R. Procedures with MCC), DRG 167 (Other Respiratory System O.R. Procedures with CC) and DRG 168 (Other Respiratory System O.R. Procedures without CC/MCC), under the surgical category “Other Respiratory System O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- BRespiratory System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 1Trachea
- 5. Approach
- 7Via Natural or Artificial Opening
Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure
- 6. Device
- CExtraluminal Device
Includes: AtriClip LAA Exclusion System; LAP-BAND(R) adjustable gastric banding system; REALIZE(R) Adjustable Gastric Band
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 04 · Diseases and Disorders of the Respiratory System · Other Respiratory System O.R. Procedures
ICD-9-CM equivalent
Converter →- 31.3Other incision of larynx or tracheaapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0BW17CZ
Is 0BW17CZ a valid ICD-10-PCS code for 2027?
- Yes. 0BW17CZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0BW17CZ an O.R. procedure?
- Yes. 0BW17CZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0BW17CZ group to?
- Depending on the principal diagnosis, 0BW17CZ can group to MS-DRG 166, MS-DRG 167 and MS-DRG 168.
What is the ICD-9 procedure code for 0BW17CZ?
- The CMS GEMs map 0BW17CZ to ICD-9-CM 31.3 (Other incision of larynx or trachea).