ICD-10-PCS 2027 procedure code
0BWL4YZRevision of Other Device in Left Lung, Percutaneous Endoscopic Approach
Short description: Revision of Other Device in Left Lung, Perc Endo Approach
Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0BWL4YZ
0BWL4YZ is the ICD-10-PCS code for a revision procedure on the left lung using a percutaneous endoscopic approach with other device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to incision of lung, the ICD-9-CM procedure title it maps to (33.1).
For a different body part, codes include 0BW04YZ (tracheobronchial tree), 0BWK4YZ (right lung), 0BWQ4YZ (pleura) and 0BWT4YZ (diaphragm).
The same procedure with a different approach is coded 0BWL0YZ (open), 0BWL3YZ (percutaneous), 0BWL7YZ (via natural or artificial opening) and 0BWL8YZ (via natural or artificial opening endoscopic).
With a different device, use 0BWL40Z (drainage device), 0BWL42Z (monitoring device) and 0BWL43Z (infusion device).
It is an operating-room procedure in the MS-DRG logic for DRG 163 (Major Chest Procedures with MCC), DRG 164 (Major Chest Procedures with CC), DRG 165 (Major Chest Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Major Chest Procedures” and “Other O.R. Procedures for Injuries”.
It was added in FY2018, effective October 1, 2017.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- BRespiratory System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- LLung, Left
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- YOther Device
Includes: Alfapump(R) system
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 04 · Diseases and Disorders of the Respiratory System · Major Chest Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 33.1Incision of lungapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2018 (effective 10/1/2017): Added
- No changes since FY2018.
Common questions about 0BWL4YZ
Is 0BWL4YZ a valid ICD-10-PCS code for 2027?
- Yes. 0BWL4YZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0BWL4YZ an O.R. procedure?
- Yes. 0BWL4YZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0BWL4YZ group to?
- Depending on the principal diagnosis, 0BWL4YZ can group to MS-DRG 163, MS-DRG 164, MS-DRG 165, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0BWL4YZ?
- The CMS GEMs map 0BWL4YZ to ICD-9-CM 33.1 (Incision of lung).