Skip to content
Dx

ICD-10-PCS 2027 procedure code

0CPS3JZRemoval of Synthetic Substitute from Larynx, Percutaneous Approach

✓ Valid for 2027O.R. procedure

Short description: Removal of Synthetic Substitute from Larynx, Perc Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0CPS3JZ

0CPS3JZ is the ICD-10-PCS code for a removal procedure on the larynx using a percutaneous approach with synthetic substitute. In ICD-10-PCS, removal means taking out or off a device from a body part.

In plain terms, this corresponds to other operations on larynx, the ICD-9-CM procedure title it maps to (31.98).

For a different body part, codes include 0CPY3JZ (mouth and throat).

The same procedure with a different approach is coded 0CPS0JZ (open), 0CPS7JZ (via natural or artificial opening), 0CPS8JZ (via natural or artificial opening endoscopic) and 0CPSXJZ (external).

With a different device, use 0CPS30Z (drainage device), 0CPS37Z (autologous tissue substitute), 0CPS3DZ (intraluminal device), 0CPS3KZ (nonautologous tissue substitute) and 0CPS3YZ (other device).

It is an operating-room procedure in the MS-DRG logic for DRG 143 (Other Ear, Nose, Mouth and Throat O.R. Procedures with MCC), DRG 144 (Other Ear, Nose, Mouth and Throat O.R. Procedures with CC), DRG 145 (Other Ear, Nose, Mouth and Throat O.R. Procedures without CC/MCC), DRG 166 (Other Respiratory System O.R. Procedures with MCC), DRG 167 (Other Respiratory System O.R. Procedures with CC) and DRG 168 (Other Respiratory System O.R. Procedures without CC/MCC), under the surgical categories “Other Ear, Nose, Mouth and Throat O.R. Procedures” and “Other Respiratory System O.R. Procedures”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
CMouth and Throat
3. Operation
PRemoval

Taking out or off a device from a body part

If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL

Includes: Drainage tube removal, cardiac pacemaker removal

4. Body Part
SLarynx

Includes: Aryepiglottic fold; Arytenoid cartilage; Corniculate cartilage; Cricoid cartilage; Cricothyroid membrane; Cuneiform cartilage; False vocal cord; Glottis; Rima glottidis; Thyroid cartilage; Ventricular fold

5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 31.98Other operations on larynxapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0CPS3JZ

Is 0CPS3JZ a valid ICD-10-PCS code for 2027?

Yes. 0CPS3JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0CPS3JZ an O.R. procedure?

Yes. 0CPS3JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0CPS3JZ group to?

Depending on the principal diagnosis, 0CPS3JZ can group to MS-DRG 143, MS-DRG 144, MS-DRG 145, MS-DRG 166, MS-DRG 167 and MS-DRG 168.

What is the ICD-9 procedure code for 0CPS3JZ?

The CMS GEMs map 0CPS3JZ to ICD-9-CM 31.98 (Other operations on larynx).