ICD-10-PCS 2027 procedure code
0CUS7JZSupplement Larynx with Synthetic Substitute, Via Natural or Artificial Opening
Short description: Supplement Larynx with Synthetic Substitute, Via Opening
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0CUS7JZ
0CUS7JZ is the ICD-10-PCS code for a supplement procedure on the larynx using a via natural or artificial opening approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to other repair of larynx, the ICD-9-CM procedure title it maps to (31.69).
For a different body part, codes include 0CUM7JZ (pharynx), 0CUR7JZ (epiglottis), 0CUT7JZ (right vocal cord) and 0CUV7JZ (left vocal cord).
The same procedure with a different approach is coded 0CUS0JZ (open) and 0CUS8JZ (via natural or artificial opening endoscopic).
With a different device, use 0CUS77Z (autologous tissue substitute) and 0CUS7KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 143 (Other Ear, Nose, Mouth and Throat O.R. Procedures with MCC), DRG 144 (Other Ear, Nose, Mouth and Throat O.R. Procedures with CC), DRG 145 (Other Ear, Nose, Mouth and Throat O.R. Procedures without CC/MCC), DRG 166 (Other Respiratory System O.R. Procedures with MCC), DRG 167 (Other Respiratory System O.R. Procedures with CC) and DRG 168 (Other Respiratory System O.R. Procedures without CC/MCC), under the surgical categories “Other Ear, Nose, Mouth and Throat O.R. Procedures”, “Other Respiratory System O.R. Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- CMouth and Throat
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- SLarynx
Includes: Aryepiglottic fold; Arytenoid cartilage; Corniculate cartilage; Cricoid cartilage; Cricothyroid membrane; Cuneiform cartilage; False vocal cord; Glottis; Rima glottidis; Thyroid cartilage; Ventricular fold
- 5. Approach
- 7Via Natural or Artificial Opening
Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 03 · Diseases and Disorders of the Ear, Nose, Mouth and Throat · Other Ear, Nose, Mouth and Throat O.R. Procedures
MDC 04 · Diseases and Disorders of the Respiratory System · Other Respiratory System O.R. Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 31.69Other repair of larynxapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0CUS7JZ
Is 0CUS7JZ a valid ICD-10-PCS code for 2027?
- Yes. 0CUS7JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0CUS7JZ an O.R. procedure?
- Yes. 0CUS7JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0CUS7JZ group to?
- Depending on the principal diagnosis, 0CUS7JZ can group to MS-DRG 143, MS-DRG 144, MS-DRG 145, MS-DRG 166, MS-DRG 167 and MS-DRG 168.
What is the ICD-9 procedure code for 0CUS7JZ?
- The CMS GEMs map 0CUS7JZ to ICD-9-CM 31.69 (Other repair of larynx).