ICD-10-PCS 2027 procedure code
0CWY01ZRevision of Radioactive Element in Mouth and Throat, Open Approach
Short description: Revision of Radioact Elem in Mouth/Throat, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0CWY01Z
0CWY01Z is the ICD-10-PCS code for a revision procedure on the mouth and throat using an open approach with radioactive element. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to incision of mouth, unspecified structure, the ICD-9-CM procedure title it maps to (27.92).
The same procedure with a different approach is coded 0CWY31Z (percutaneous), 0CWY71Z (via natural or artificial opening), 0CWY81Z (via natural or artificial opening endoscopic) and 0CWYX1Z (external).
With a different device, use 0CWY00Z (drainage device), 0CWY07Z (autologous tissue substitute), 0CWY0DZ (intraluminal device), 0CWY0JZ (synthetic substitute), 0CWY0KZ (nonautologous tissue substitute) and 0CWY0YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 137 (Mouth Procedures with CC/MCC), DRG 138 (Mouth Procedures without CC/MCC), DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), DRG 580 (Other Skin, Subcutaneous Tissue and Breast Procedures with CC), DRG 581 (Other Skin, Subcutaneous Tissue and Breast Procedures without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Mouth Procedures”, “Other Skin, Subcutaneous Tissue and Breast Procedures”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- CMouth and Throat
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- YMouth and Throat
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 1Radioactive Element
Includes: Brachytherapy seeds; CivaSheet(R)
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 03 · Diseases and Disorders of the Ear, Nose, Mouth and Throat · Mouth Procedures
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Other Skin, Subcutaneous Tissue and Breast Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 27.92Incision of mouth, unspecified structureapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0CWY01Z
Is 0CWY01Z a valid ICD-10-PCS code for 2027?
- Yes. 0CWY01Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0CWY01Z an O.R. procedure?
- Yes. 0CWY01Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0CWY01Z group to?
- Depending on the principal diagnosis, 0CWY01Z can group to MS-DRG 137, MS-DRG 138, MS-DRG 579, MS-DRG 580, MS-DRG 581 and MS-DRG 907.
What is the ICD-9 procedure code for 0CWY01Z?
- The CMS GEMs map 0CWY01Z to ICD-9-CM 27.92 (Incision of mouth, unspecified structure).