Skip to content
Dx

ICD-10-PCS 2027 procedure code

0CWY7DZRevision of Intraluminal Device in Mouth and Throat, Via Natural or Artificial Opening

✓ Valid for 2027O.R. procedure

Short description: Revision of Intraluminal Device in Mouth/Throat, Via Opening

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0CWY7DZ

0CWY7DZ is the ICD-10-PCS code for a revision procedure on the mouth and throat using a via natural or artificial opening approach with intraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Pharyngotomy, the ICD-9-CM procedure title it maps to (29.0).

For a different body part, codes include 0CWS7DZ (larynx).

The same procedure with a different approach is coded 0CWY0DZ (open), 0CWY3DZ (percutaneous), 0CWY8DZ (via natural or artificial opening endoscopic) and 0CWYXDZ (external).

With a different device, use 0CWY70Z (drainage device), 0CWY71Z (radioactive element), 0CWY77Z (autologous tissue substitute), 0CWY7JZ (synthetic substitute), 0CWY7KZ (nonautologous tissue substitute) and 0CWY7YZ (other device).

It is an operating-room procedure in the MS-DRG logic for DRG 143 (Other Ear, Nose, Mouth and Throat O.R. Procedures with MCC), DRG 144 (Other Ear, Nose, Mouth and Throat O.R. Procedures with CC), DRG 145 (Other Ear, Nose, Mouth and Throat O.R. Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Other Ear, Nose, Mouth and Throat O.R. Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
CMouth and Throat
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
YMouth and Throat
5. Approach
7Via Natural or Artificial Opening

Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure

6. Device
DIntraluminal Device

Includes: Absolute Pro Vascular (OTW) Self-Expanding Stent System; Acculink (RX) Carotid Stent System; AFX(R) Endovascular AAA System; AneuRx(R) AAA Advantage(R); Assurant (Cobalt) stent; Carotid WALLSTENT(R) Monorail(R) Endoprosthesis; CoAxia NeuroFlo catheter; Colonic Z-Stent(R); Complete (SE) stent; Cook Zenith AAA Endovascular Graft; Driver stent (RX) (OTW); E-Luminexx(tm) (Biliary)(Vascular) Stent; Embolization coil(s); Endologix AFX(R) Endovascular AAA System; Endurant(R) Endovascular Stent Graft; Endurant(R) II AAA stent graft system; EXCLUDER(R) AAA Endoprosthesis; Express(R) (LD) Premounted Stent System; Express(R) Biliary SD Monorail(R) Premounted Stent System; Express(R) SD Renal Monorail(R) Premounted Stent System; FLAIR(R) Endovascular Stent Graft; Formula(tm) Balloon-Expandable Renal Stent System; GORE EXCLUDER(R) AAA Endoprosthesis; GORE TAG(R) Thoracic Endoprosthesis; GORE(R) VIABAHN(R) Endoprosthesis; GORE(R) VIABIL(R) Biliary Endoprosthesis; Herculink (RX) Elite Renal Stent System; Innova(tm) stent; LifeStent(R) (Flexstar)(XL) Vascular Stent System; Medtronic Endurant(R) II AAA stent graft system; Micro-Driver stent (RX) (OTW); MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System; Omnilink Elite Vascular Balloon Expandable Stent System; Protege(R) RX Carotid Stent System; Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary); Talent(R) Converter; Talent(R) Occluder; Talent(R) Stent Graft (abdominal)(thoracic); Therapeutic occlusion coil(s); Ultraflex(tm) Precision Colonic Stent System; Valiant Thoracic Stent Graft; WALLSTENT(R) Endoprosthesis; Xact Carotid Stent System; Zenith AAA Endovascular Graft; Zenith Flex(R) AAA Endovascular Graft; Zenith TX2(R) TAA Endovascular Graft; Zenith(R) Renu(tm) AAA Ancillary Graft

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 29.0Pharyngotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0CWY7DZ

Is 0CWY7DZ a valid ICD-10-PCS code for 2027?

Yes. 0CWY7DZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0CWY7DZ an O.R. procedure?

Yes. 0CWY7DZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0CWY7DZ group to?

Depending on the principal diagnosis, 0CWY7DZ can group to MS-DRG 143, MS-DRG 144, MS-DRG 145, MS-DRG 907, MS-DRG 908 and MS-DRG 909.

What is the ICD-9 procedure code for 0CWY7DZ?

The CMS GEMs map 0CWY7DZ to ICD-9-CM 29.0 (Pharyngotomy).