ICD-10-PCS 2027 procedure code
0DU67JZSupplement Stomach with Synthetic Substitute, Via Natural or Artificial Opening
Short description: Supplement Stomach with Synthetic Substitute, Via Opening
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0DU67JZ
0DU67JZ is the ICD-10-PCS code for a supplement procedure on the stomach using a via natural or artificial opening approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to other repair of stomach, the ICD-9-CM procedure title it maps to (44.69).
For a different body part, codes include 0DU17JZ (esophagus, upper), 0DU27JZ (esophagus, middle), 0DU37JZ (esophagus, lower), 0DU47JZ (esophagogastric junction), 0DU57JZ (esophagus), 0DU77JZ (stomach, pylorus) and 15 more.
The same procedure with a different approach is coded 0DU60JZ (open), 0DU64JZ (percutaneous endoscopic) and 0DU68JZ (via natural or artificial opening endoscopic).
With a different device, use 0DU677Z (autologous tissue substitute) and 0DU67KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 326 (Stomach, Esophageal and Duodenal Procedures with MCC), DRG 327 (Stomach, Esophageal and Duodenal Procedures with CC), DRG 328 (Stomach, Esophageal and Duodenal Procedures without CC/MCC), DRG 619 (O.R. Procedures for Obesity with MCC), DRG 620 (O.R. Procedures for Obesity with CC) and DRG 621 (O.R. Procedures for Obesity without CC/MCC), under the surgical categories “Stomach, Esophageal and Duodenal Procedures”, “O.R. Procedures for Obesity”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- DGastrointestinal System
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- 6Stomach
- 5. Approach
- 7Via Natural or Artificial Opening
Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 06 · Diseases and Disorders of the Digestive System · Stomach, Esophageal and Duodenal Procedures
MDC 10 · Endocrine, Nutritional and Metabolic Diseases and Disorders · O.R. Procedures for Obesity
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 44.69Other repair of stomachapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0DU67JZ
Is 0DU67JZ a valid ICD-10-PCS code for 2027?
- Yes. 0DU67JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0DU67JZ an O.R. procedure?
- Yes. 0DU67JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0DU67JZ group to?
- Depending on the principal diagnosis, 0DU67JZ can group to MS-DRG 326, MS-DRG 327, MS-DRG 328, MS-DRG 619, MS-DRG 620 and MS-DRG 621.
What is the ICD-9 procedure code for 0DU67JZ?
- The CMS GEMs map 0DU67JZ to ICD-9-CM 44.69 (Other repair of stomach).