Skip to content
Dx

ICD-10-PCS 2027 procedure code

0DUU4JZSupplement Omentum with Synthetic Substitute, Percutaneous Endoscopic Approach

✓ Valid for 2027O.R. procedure

Short description: Supplement Omentum with Synth Sub, Perc Endo Approach

Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0DUU4JZ

0DUU4JZ is the ICD-10-PCS code for a supplement procedure on the omentum using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.

In plain terms, this corresponds to other repair of omentum, the ICD-9-CM procedure title it maps to (54.74).

For a different body part, codes include 0DU14JZ (esophagus, upper), 0DU24JZ (esophagus, middle), 0DU34JZ (esophagus, lower), 0DU44JZ (esophagogastric junction), 0DU54JZ (esophagus), 0DU64JZ (stomach) and 19 more.

The same procedure with a different approach is coded 0DUU0JZ (open).

With a different device, use 0DUU47Z (autologous tissue substitute) and 0DUU4KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 356 (Other Digestive System O.R. Procedures with MCC), DRG 357 (Other Digestive System O.R. Procedures with CC), DRG 358 (Other Digestive System O.R. Procedures without CC/MCC), DRG 423 (Other Hepatobiliary or Pancreas O.R. Procedures with MCC), DRG 424 (Other Hepatobiliary or Pancreas O.R. Procedures with CC) and DRG 425 (Other Hepatobiliary or Pancreas O.R. Procedures without CC/MCC), under the surgical categories “Other Digestive System O.R. Procedures”, “Other Hepatobiliary or Pancreas O.R. Procedures”, “Lymphoma and Leukemia with Major O.R. Procedures” and 3 more.

It was added in FY2018, effective October 1, 2017.

What each character means

1. Section
0Medical and Surgical
2. Body System
DGastrointestinal System
3. Operation
USupplement

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part

Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement

4. Body Part
UOmentum

Includes: Gastrocolic ligament; Gastrocolic omentum; Gastrohepatic omentum; Gastrophrenic ligament; Gastrosplenic ligament; Greater Omentum; Hepatogastric ligament; Lesser Omentum

5. Approach
4Percutaneous Endoscopic

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 54.74Other repair of omentumapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2018 (effective 10/1/2017): Added
  • No changes since FY2018.

Common questions about 0DUU4JZ

Is 0DUU4JZ a valid ICD-10-PCS code for 2027?

Yes. 0DUU4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0DUU4JZ an O.R. procedure?

Yes. 0DUU4JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0DUU4JZ group to?

Depending on the principal diagnosis, 0DUU4JZ can group to MS-DRG 356, MS-DRG 357, MS-DRG 358, MS-DRG 423, MS-DRG 424 and MS-DRG 425.

What is the ICD-9 procedure code for 0DUU4JZ?

The CMS GEMs map 0DUU4JZ to ICD-9-CM 54.74 (Other repair of omentum).