ICD-10-PCS 2027 procedure code
0DW07DZRevision of Intraluminal Device in Upper Intestinal Tract, Via Natural or Artificial Opening
Short description: Revision of Intralum Dev in Up Intest Tract, Via Opening
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0DW07DZ
0DW07DZ is the ICD-10-PCS code for a revision procedure on the upper intestinal tract using a via natural or artificial opening approach with intraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of small intestine, the ICD-9-CM procedure title it maps to (45.02).
For a different body part, codes include 0DW57DZ (esophagus), 0DW67DZ (stomach) and 0DWD7DZ (lower intestinal tract).
The same procedure with a different approach is coded 0DW00DZ (open), 0DW03DZ (percutaneous), 0DW04DZ (percutaneous endoscopic), 0DW08DZ (via natural or artificial opening endoscopic) and 0DW0XDZ (external).
With a different device, use 0DW070Z (drainage device), 0DW072Z (monitoring device), 0DW073Z (infusion device), 0DW077Z (autologous tissue substitute), 0DW07CZ (extraluminal device), 0DW07JZ (synthetic substitute) and 3 more.
It is an operating-room procedure in the MS-DRG logic for DRG 344 (Minor Small and Large Bowel Procedures with MCC), DRG 345 (Minor Small and Large Bowel Procedures with CC), DRG 346 (Minor Small and Large Bowel Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Minor Small and Large Bowel Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- DGastrointestinal System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 0Upper Intestinal Tract
- 5. Approach
- 7Via Natural or Artificial Opening
Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure
- 6. Device
- DIntraluminal Device
Includes: Absolute Pro Vascular (OTW) Self-Expanding Stent System; Acculink (RX) Carotid Stent System; AFX(R) Endovascular AAA System; AneuRx(R) AAA Advantage(R); Assurant (Cobalt) stent; Carotid WALLSTENT(R) Monorail(R) Endoprosthesis; CoAxia NeuroFlo catheter; Colonic Z-Stent(R); Complete (SE) stent; Cook Zenith AAA Endovascular Graft; Driver stent (RX) (OTW); E-Luminexx(tm) (Biliary)(Vascular) Stent; Embolization coil(s); Endologix AFX(R) Endovascular AAA System; Endurant(R) Endovascular Stent Graft; Endurant(R) II AAA stent graft system; EXCLUDER(R) AAA Endoprosthesis; Express(R) (LD) Premounted Stent System; Express(R) Biliary SD Monorail(R) Premounted Stent System; Express(R) SD Renal Monorail(R) Premounted Stent System; FLAIR(R) Endovascular Stent Graft; Formula(tm) Balloon-Expandable Renal Stent System; GORE EXCLUDER(R) AAA Endoprosthesis; GORE TAG(R) Thoracic Endoprosthesis; GORE(R) VIABAHN(R) Endoprosthesis; GORE(R) VIABIL(R) Biliary Endoprosthesis; Herculink (RX) Elite Renal Stent System; Innova(tm) stent; LifeStent(R) (Flexstar)(XL) Vascular Stent System; Medtronic Endurant(R) II AAA stent graft system; Micro-Driver stent (RX) (OTW); MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System; Omnilink Elite Vascular Balloon Expandable Stent System; Protege(R) RX Carotid Stent System; Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary); Talent(R) Converter; Talent(R) Occluder; Talent(R) Stent Graft (abdominal)(thoracic); Therapeutic occlusion coil(s); Ultraflex(tm) Precision Colonic Stent System; Valiant Thoracic Stent Graft; WALLSTENT(R) Endoprosthesis; Xact Carotid Stent System; Zenith AAA Endovascular Graft; Zenith Flex(R) AAA Endovascular Graft; Zenith TX2(R) TAA Endovascular Graft; Zenith(R) Renu(tm) AAA Ancillary Graft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 06 · Diseases and Disorders of the Digestive System · Minor Small and Large Bowel Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 45.02Other incision of small intestineapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0DW07DZ
Is 0DW07DZ a valid ICD-10-PCS code for 2027?
- Yes. 0DW07DZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0DW07DZ an O.R. procedure?
- Yes. 0DW07DZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0DW07DZ group to?
- Depending on the principal diagnosis, 0DW07DZ can group to MS-DRG 344, MS-DRG 345, MS-DRG 346, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0DW07DZ?
- The CMS GEMs map 0DW07DZ to ICD-9-CM 45.02 (Other incision of small intestine).