ICD-10-PCS 2027 procedure code
0DW600ZRevision of Drainage Device in Stomach, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0DW600Z
0DW600Z is the ICD-10-PCS code for a revision procedure on the stomach using an open approach with drainage device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to Gastrotomy, the ICD-9-CM procedure title it maps to (43.0).
For a different body part, codes include 0DW000Z (upper intestinal tract), 0DWD00Z (lower intestinal tract), 0DWU00Z (omentum), 0DWV00Z (mesentery) and 0DWW00Z (peritoneum).
The same procedure with a different approach is coded 0DW630Z (percutaneous), 0DW640Z (percutaneous endoscopic), 0DW670Z (via natural or artificial opening), 0DW680Z (via natural or artificial opening endoscopic) and 0DW6X0Z (external).
With a different device, use 0DW602Z (monitoring device), 0DW603Z (infusion device), 0DW607Z (autologous tissue substitute), 0DW60CZ (extraluminal device), 0DW60DZ (intraluminal device), 0DW60JZ (synthetic substitute) and 4 more.
It is an operating-room procedure in the MS-DRG logic for DRG 326 (Stomach, Esophageal and Duodenal Procedures with MCC), DRG 327 (Stomach, Esophageal and Duodenal Procedures with CC), DRG 328 (Stomach, Esophageal and Duodenal Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Stomach, Esophageal and Duodenal Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- DGastrointestinal System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 6Stomach
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 0Drainage Device
Includes: Cystostomy tube; Foley catheter; Percutaneous nephrostomy catheter; Thoracostomy tube
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 06 · Diseases and Disorders of the Digestive System · Stomach, Esophageal and Duodenal Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 43.0Gastrotomyapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0DW600Z
Is 0DW600Z a valid ICD-10-PCS code for 2027?
- Yes. 0DW600Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0DW600Z an O.R. procedure?
- Yes. 0DW600Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0DW600Z group to?
- Depending on the principal diagnosis, 0DW600Z can group to MS-DRG 326, MS-DRG 327, MS-DRG 328, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0DW600Z?
- The CMS GEMs map 0DW600Z to ICD-9-CM 43.0 (Gastrotomy).