ICD-10-PCS 2027 procedure code
0DWU07ZRevision of Autologous Tissue Substitute in Omentum, Open Approach
Short description: Revision of Autol Sub in Omentum, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0DWU07Z
0DWU07Z is the ICD-10-PCS code for a revision procedure on the omentum using an open approach with autologous tissue substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to incision of peritoneum, the ICD-9-CM procedure title it maps to (54.95).
For a different body part, codes include 0DW007Z (upper intestinal tract), 0DW607Z (stomach), 0DW807Z (small intestine), 0DWD07Z (lower intestinal tract), 0DWE07Z (large intestine), 0DWV07Z (mesentery) and 1 more.
The same procedure with a different approach is coded 0DWU37Z (percutaneous) and 0DWU47Z (percutaneous endoscopic).
With a different device, use 0DWU00Z (drainage device), 0DWU0JZ (synthetic substitute) and 0DWU0KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 356 (Other Digestive System O.R. Procedures with MCC), DRG 357 (Other Digestive System O.R. Procedures with CC) and DRG 358 (Other Digestive System O.R. Procedures without CC/MCC), under the surgical category “Other Digestive System O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- DGastrointestinal System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- UOmentum
Includes: Gastrocolic ligament; Gastrocolic omentum; Gastrohepatic omentum; Gastrophrenic ligament; Gastrosplenic ligament; Greater Omentum; Hepatogastric ligament; Lesser Omentum
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 7Autologous Tissue Substitute
Includes: Autograft; Cultured epidermal cell autograft; Epicel(R) cultured epidermal autograft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 06 · Diseases and Disorders of the Digestive System · Other Digestive System O.R. Procedures
ICD-9-CM equivalent
Converter →- 54.95Incision of peritoneumapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0DWU07Z
Is 0DWU07Z a valid ICD-10-PCS code for 2027?
- Yes. 0DWU07Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0DWU07Z an O.R. procedure?
- Yes. 0DWU07Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0DWU07Z group to?
- Depending on the principal diagnosis, 0DWU07Z can group to MS-DRG 356, MS-DRG 357 and MS-DRG 358.
What is the ICD-9 procedure code for 0DWU07Z?
- The CMS GEMs map 0DWU07Z to ICD-9-CM 54.95 (Incision of peritoneum).