Skip to content
Dx

ICD-10-PCS 2027 procedure code

0FUD8JZSupplement Pancreatic Duct with Synthetic Substitute, Via Natural or Artificial Opening Endoscopic

✓ Valid for 2027O.R. procedure

Short description: Supplement Pancreatic Duct with Synthetic Substitute, Endo

Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0FUD8JZ

0FUD8JZ is the ICD-10-PCS code for a supplement procedure on the pancreatic duct using a via natural or artificial opening endoscopic approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.

In plain terms, this corresponds to other repair of pancreas, the ICD-9-CM procedure title it maps to (52.95).

For a different body part, codes include 0FU58JZ (right hepatic duct), 0FU68JZ (left hepatic duct), 0FU78JZ (hepatic duct, common), 0FU88JZ (cystic duct), 0FU98JZ (common bile duct), 0FUC8JZ (ampulla of vater) and 1 more.

The same procedure with a different approach is coded 0FUD0JZ (open), 0FUD3JZ (percutaneous) and 0FUD4JZ (percutaneous endoscopic).

With a different device, use 0FUD87Z (autologous tissue substitute) and 0FUD8KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 405 (Pancreas, Liver and Shunt Procedures with MCC), DRG 406 (Pancreas, Liver and Shunt Procedures with CC), DRG 407 (Pancreas, Liver and Shunt Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Pancreas, Liver and Shunt Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.

It was added in FY2018, effective October 1, 2017.

What each character means

1. Section
0Medical and Surgical
2. Body System
FHepatobiliary System and Pancreas
3. Operation
USupplement

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part

Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement

4. Body Part
DPancreatic Duct

Includes: Duct of Wirsung

5. Approach
8Via Natural or Artificial Opening Endoscopic

Entry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 52.95Other repair of pancreasapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2018 (effective 10/1/2017): Added
  • No changes since FY2018.

Common questions about 0FUD8JZ

Is 0FUD8JZ a valid ICD-10-PCS code for 2027?

Yes. 0FUD8JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0FUD8JZ an O.R. procedure?

Yes. 0FUD8JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0FUD8JZ group to?

Depending on the principal diagnosis, 0FUD8JZ can group to MS-DRG 405, MS-DRG 406, MS-DRG 407, MS-DRG 907, MS-DRG 908 and MS-DRG 909.

What is the ICD-9 procedure code for 0FUD8JZ?

The CMS GEMs map 0FUD8JZ to ICD-9-CM 52.95 (Other repair of pancreas).