Skip to content
Dx

ICD-10-PCS 2027 procedure code

0FW032ZRevision of Monitoring Device in Liver, Percutaneous Approach

✓ Valid for 2027O.R. procedure

Short description: Revision of Monitoring Device in Liver, Perc Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0FW032Z

0FW032Z is the ICD-10-PCS code for a revision procedure on the liver using a percutaneous approach with monitoring device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Hepatotomy, the ICD-9-CM procedure title it maps to (50.0).

For a different body part, codes include 0FW432Z (gallbladder), 0FWB32Z (hepatobiliary duct), 0FWD32Z (pancreatic duct) and 0FWG32Z (pancreas).

The same procedure with a different approach is coded 0FW002Z (open), 0FW042Z (percutaneous endoscopic) and 0FW0X2Z (external).

With a different device, use 0FW030Z (drainage device), 0FW033Z (infusion device) and 0FW03YZ (other device).

It is an operating-room procedure in the MS-DRG logic for DRG 405 (Pancreas, Liver and Shunt Procedures with MCC), DRG 406 (Pancreas, Liver and Shunt Procedures with CC), DRG 407 (Pancreas, Liver and Shunt Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Pancreas, Liver and Shunt Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
FHepatobiliary System and Pancreas
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
0Liver

Includes: Quadrate lobe

5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
2Monitoring Device

Includes: Blood glucose monitoring system; Cardiac event recorder; Continuous Glucose Monitoring (CGM) device; Implantable glucose monitoring device; Loop recorder, implantable; Reveal (LINQ)(DX)(XT)

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 50.0Hepatotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0FW032Z

Is 0FW032Z a valid ICD-10-PCS code for 2027?

Yes. 0FW032Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0FW032Z an O.R. procedure?

Yes. 0FW032Z is an O.R. procedure in MS-DRG v44.0.

What DRG does 0FW032Z group to?

Depending on the principal diagnosis, 0FW032Z can group to MS-DRG 405, MS-DRG 406, MS-DRG 407, MS-DRG 907, MS-DRG 908 and MS-DRG 909.

What is the ICD-9 procedure code for 0FW032Z?

The CMS GEMs map 0FW032Z to ICD-9-CM 50.0 (Hepatotomy).