ICD-10-PCS 2027 procedure code
0HUX7JZSupplement Left Nipple with Synthetic Substitute, Via Natural or Artificial Opening
Short description: Supplement Left Nipple with Synth Sub, Via Opening
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0HUX7JZ
0HUX7JZ is the ICD-10-PCS code for a supplement procedure on the left nipple using a via natural or artificial opening approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to other repair or reconstruction of nipple, the ICD-9-CM procedure title it maps to (85.87).
For a different body part, codes include 0HUT7JZ (right breast), 0HUU7JZ (left breast), 0HUV7JZ (bilateral breast) and 0HUW7JZ (right nipple).
The same procedure with a different approach is coded 0HUX0JZ (open), 0HUX3JZ (percutaneous), 0HUX8JZ (via natural or artificial opening endoscopic) and 0HUXXJZ (external).
With a different device, use 0HUX77Z (autologous tissue substitute) and 0HUX7KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 584 (Breast Biopsy, Local Excision and Other Breast Procedures with CC/MCC), DRG 585 (Breast Biopsy, Local Excision and Other Breast Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC), DRG 909 (Other O.R. Procedures for Injuries without CC/MCC) and DRG 957 (Other O.R. Procedures for Multiple Significant Trauma with MCC), under the surgical categories “Breast Biopsy, Local Excision and Other Breast Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- HSkin and Breast
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- XNipple, Left
Includes: Areola
- 5. Approach
- 7Via Natural or Artificial Opening
Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Breast Biopsy, Local Excision and Other Breast Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 85.87Other repair or reconstruction of nippleapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0HUX7JZ
Is 0HUX7JZ a valid ICD-10-PCS code for 2027?
- Yes. 0HUX7JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0HUX7JZ an O.R. procedure?
- Yes. 0HUX7JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0HUX7JZ group to?
- Depending on the principal diagnosis, 0HUX7JZ can group to MS-DRG 584, MS-DRG 585, MS-DRG 907, MS-DRG 908, MS-DRG 909 and MS-DRG 957.
What is the ICD-9 procedure code for 0HUX7JZ?
- The CMS GEMs map 0HUX7JZ to ICD-9-CM 85.87 (Other repair or reconstruction of nipple).