Skip to content
Dx

ICD-10-PCS 2027 procedure code

0JH800ZInsertion of Hemodynamic Monitoring Device into Abdomen Subcutaneous Tissue and Fascia, Open Approach

✓ Valid for 2027O.R. procedure

Short description: Insert Hemodyn Monitor Dev in Abd Subcu/Fascia, Open

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0JH800Z

0JH800Z is the ICD-10-PCS code for a insertion procedure on the subcutaneous tissue and fascia, abdomen using an open approach with monitoring device, hemodynamic. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.

In plain terms, this corresponds to implantation or replacement of subcutaneous device for intracardiac or great vessel hemodynamic monitoring, the ICD-9-CM procedure title it maps to (00.57).

For a different body part, codes include 0JH600Z (subcutaneous tissue and fascia, chest).

The same procedure with a different approach is coded 0JH830Z (percutaneous).

With a different device, use 0JH802Z (monitoring device), 0JH804Z (pacemaker, single chamber), 0JH805Z (pacemaker, single chamber rate responsive), 0JH806Z (pacemaker, dual chamber), 0JH807Z (cardiac resynchronization pacemaker pulse generator), 0JH808Z (defibrillator generator) and 14 more.

It is an operating-room procedure in the MS-DRG logic for DRG 210 (Cardiac Pacemaker Revision or Device Replacement with MCC) and DRG 211 (Cardiac Pacemaker Revision or Device Replacement without MCC), under the surgical category “Cardiac Pacemaker Revision or Device Replacement”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
JSubcutaneous Tissue and Fascia
3. Operation
HInsertion

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Includes: Insertion of radioactive implant, insertion of central venous catheter

4. Body Part
8Subcutaneous Tissue and Fascia, Abdomen
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
0Monitoring Device, Hemodynamic
7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Pacemaker Revision or Device Replacement

ICD-9-CM equivalent

Converter →
  • 00.57Implantation or replacement of subcutaneous device for intracardiac or great vessel hemodynamic monitoringapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0JH800Z

Is 0JH800Z a valid ICD-10-PCS code for 2027?

Yes. 0JH800Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0JH800Z an O.R. procedure?

Yes. 0JH800Z is an O.R. procedure in MS-DRG v44.0.

What DRG does 0JH800Z group to?

Depending on the principal diagnosis, 0JH800Z can group to MS-DRG 210 and MS-DRG 211.

What is the ICD-9 procedure code for 0JH800Z?

The CMS GEMs map 0JH800Z to ICD-9-CM 00.57 (Implantation or replacement of subcutaneous device for intracardiac or great vessel hemodynamic monitoring).