Skip to content
Dx

ICD-10-PCS 2027 procedure code

0JH837ZInsertion of Cardiac Resynchronization Pacemaker Pulse Generator into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach

✓ Valid for 2027Non-O.R. procedure

Short description: Insert Card Rsync Pace Puls Gen in Abd Subcu/Fascia, Perc

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0JH837Z

0JH837Z is the ICD-10-PCS code for a insertion procedure on the subcutaneous tissue and fascia, abdomen using a percutaneous approach with cardiac resynchronization pacemaker pulse generator. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.

In plain terms, this corresponds to implantation or replacement of cardiac resynchronization pacemaker pulse generator only [CRT-P], the ICD-9-CM procedure title it maps to (00.53).

For a different body part, codes include 0JH637Z (subcutaneous tissue and fascia, chest).

The same procedure with a different approach is coded 0JH807Z (open).

With a different device, use 0JH830Z (monitoring device, hemodynamic), 0JH832Z (monitoring device), 0JH834Z (pacemaker, single chamber), 0JH835Z (pacemaker, single chamber rate responsive), 0JH836Z (pacemaker, dual chamber), 0JH838Z (defibrillator generator) and 14 more.

It is a non-O.R. procedure that is part of the MS-DRG logic for DRG 210 (Cardiac Pacemaker Revision or Device Replacement with MCC), DRG 211 (Cardiac Pacemaker Revision or Device Replacement without MCC), DRG 242 (Permanent Cardiac Pacemaker Implant with MCC), DRG 243 (Permanent Cardiac Pacemaker Implant with CC) and DRG 244 (Permanent Cardiac Pacemaker Implant without CC/MCC), under the surgical categories “Cardiac Pacemaker Revision or Device Replacement” and “Permanent Cardiac Pacemaker Implant”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
JSubcutaneous Tissue and Fascia
3. Operation
HInsertion

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Includes: Insertion of radioactive implant, insertion of central venous catheter

4. Body Part
8Subcutaneous Tissue and Fascia, Abdomen
5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
7Cardiac Resynchronization Pacemaker Pulse Generator
7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Pacemaker Revision or Device Replacement

ICD-9-CM equivalent

Converter →
  • 00.53Implantation or replacement of cardiac resynchronization pacemaker pulse generator only [CRT-P]approximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0JH837Z

Is 0JH837Z a valid ICD-10-PCS code for 2027?

Yes. 0JH837Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0JH837Z an O.R. procedure?

No. 0JH837Z is designated non-O.R. in MS-DRG v44.0.

What DRG does 0JH837Z group to?

Depending on the principal diagnosis, 0JH837Z can group to MS-DRG 210, MS-DRG 211, MS-DRG 242, MS-DRG 243 and MS-DRG 244.

What is the ICD-9 procedure code for 0JH837Z?

The CMS GEMs map 0JH837Z to ICD-9-CM 00.53 (Implantation or replacement of cardiac resynchronization pacemaker pulse generator only [CRT-P]).