Skip to content
Dx

ICD-10-PCS 2027 procedure code

0JUG3JZSupplement of Right Lower Arm Subcutaneous Tissue and Fascia with Synthetic Substitute, Percutaneous Approach

✓ Valid for 2027O.R. procedure

Short description: Supplement R Low Arm Subcu/Fascia w Synth Sub, Perc

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0JUG3JZ

0JUG3JZ is the ICD-10-PCS code for a supplement procedure on the subcutaneous tissue and fascia, right lower arm using a percutaneous approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.

In plain terms, this corresponds to graft of muscle or fascia, the ICD-9-CM procedure title it maps to (83.82).

For a different body part, codes include 0JU03JZ (subcutaneous tissue and fascia, scalp), 0JU13JZ (subcutaneous tissue and fascia, face), 0JU43JZ (subcutaneous tissue and fascia, right neck), 0JU53JZ (subcutaneous tissue and fascia, left neck), 0JU63JZ (subcutaneous tissue and fascia, chest), 0JU73JZ (subcutaneous tissue and fascia, back) and 15 more.

The same procedure with a different approach is coded 0JUG0JZ (open).

With a different device, use 0JUG37Z (autologous tissue substitute) and 0JUG3KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 500 (Soft Tissue Procedures with MCC), DRG 501 (Soft Tissue Procedures with CC), DRG 502 (Soft Tissue Procedures without CC/MCC), DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), DRG 580 (Other Skin, Subcutaneous Tissue and Breast Procedures with CC) and DRG 581 (Other Skin, Subcutaneous Tissue and Breast Procedures without CC/MCC), under the surgical categories “Soft Tissue Procedures”, “Other Skin, Subcutaneous Tissue and Breast Procedures” and “Other O.R. Procedures for Injuries”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
JSubcutaneous Tissue and Fascia
3. Operation
USupplement

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part

Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement

4. Body Part
GSubcutaneous Tissue and Fascia, Right Lower Arm

Includes: Antebrachial fascia; Bicipital aponeurosis

5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 83.82Graft of muscle or fasciaapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0JUG3JZ

Is 0JUG3JZ a valid ICD-10-PCS code for 2027?

Yes. 0JUG3JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0JUG3JZ an O.R. procedure?

Yes. 0JUG3JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0JUG3JZ group to?

Depending on the principal diagnosis, 0JUG3JZ can group to MS-DRG 500, MS-DRG 501, MS-DRG 502, MS-DRG 579, MS-DRG 580 and MS-DRG 581.

What is the ICD-9 procedure code for 0JUG3JZ?

The CMS GEMs map 0JUG3JZ to ICD-9-CM 83.82 (Graft of muscle or fascia).