ICD-10-PCS 2027 procedure code
0JWT32ZRevision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach
Short description: Revision of Monitor Dev in Trunk Subcu/Fascia, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0JWT32Z
0JWT32Z is the ICD-10-PCS code for a revision procedure on the subcutaneous tissue and fascia, trunk using a percutaneous approach with monitoring device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to revision or relocation of cardiac device pocket and other incision of skin and subcutaneous tissue, the ICD-9-CM procedure titles it maps to (37.79 and 86.09).
The same procedure with a different approach is coded 0JWT02Z (open) and 0JWTX2Z (external).
With a different device, use 0JWT30Z (drainage device), 0JWT33Z (infusion device), 0JWT37Z (autologous tissue substitute), 0JWT3FZ (subcutaneous defibrillator lead), 0JWT3HZ (contraceptive device), 0JWT3JZ (synthetic substitute) and 8 more.
It is an operating-room procedure in the MS-DRG logic for DRG 040 (Peripheral, Cranial Nerve and Other Nervous System Procedures with MCC), DRG 041 (Peripheral, Cranial Nerve and Other Nervous System Procedures with CC or Peripheral Neurostimulator), DRG 042 (Peripheral, Cranial Nerve and Other Nervous System Procedures without CC/MCC), DRG 210 (Cardiac Pacemaker Revision or Device Replacement with MCC), DRG 211 (Cardiac Pacemaker Revision or Device Replacement without MCC) and DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), under the surgical categories “Peripheral, Cranial Nerve and Other Nervous System Procedures”, “Cardiac Pacemaker Revision or Device Replacement”, “Other Skin, Subcutaneous Tissue and Breast Procedures” and 2 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- JSubcutaneous Tissue and Fascia
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- TSubcutaneous Tissue and Fascia, Trunk
Includes: External oblique aponeurosis; Transversalis fascia
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 2Monitoring Device
Includes: Blood glucose monitoring system; Cardiac event recorder; Continuous Glucose Monitoring (CGM) device; Implantable glucose monitoring device; Loop recorder, implantable; Reveal (LINQ)(DX)(XT)
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different approach
Different device
- 0JWT30ZDrainage Device
- 0JWT33ZInfusion Device
- 0JWT37ZAutologous Tissue Substitute
- 0JWT3FZSubcutaneous Defibrillator Lead
- 0JWT3HZContraceptive Device
- 0JWT3JZSynthetic Substitute
- 0JWT3KZNonautologous Tissue Substitute
- 0JWT3MZStimulator Generator
- 0JWT3NZTissue Expander
- 0JWT3PZCardiac Rhythm Related Device
- 0JWT3VZInfusion Device, Pump
- 0JWT3WZVascular Access Device, Totally Implantable
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Peripheral, Cranial Nerve and Other Nervous System Procedures
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Pacemaker Revision or Device Replacement
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Other Skin, Subcutaneous Tissue and Breast Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 37.79Revision or relocation of cardiac device pocketapproximate
- 86.09Other incision of skin and subcutaneous tissueapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0JWT32Z
Is 0JWT32Z a valid ICD-10-PCS code for 2027?
- Yes. 0JWT32Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0JWT32Z an O.R. procedure?
- Yes. 0JWT32Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0JWT32Z group to?
- Depending on the principal diagnosis, 0JWT32Z can group to MS-DRG 040, MS-DRG 041, MS-DRG 042, MS-DRG 210, MS-DRG 211 and MS-DRG 579.
What is the ICD-9 procedure code for 0JWT32Z?
- The CMS GEMs map 0JWT32Z to ICD-9-CM 37.79 (Revision or relocation of cardiac device pocket) and 86.09 (Other incision of skin and subcutaneous tissue).