ICD-10-PCS 2027 procedure code
0JWV0JZRevision of Synthetic Substitute in Upper Extremity Subcutaneous Tissue and Fascia, Open Approach
Short description: Revise of Synth Sub in Up Extrem Subcu/Fascia, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0JWV0JZ
0JWV0JZ is the ICD-10-PCS code for a revision procedure on the subcutaneous tissue and fascia, upper extremity using an open approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of skin and subcutaneous tissue, the ICD-9-CM procedure title it maps to (86.09).
For a different body part, codes include 0JWS0JZ (subcutaneous tissue and fascia, head and neck), 0JWT0JZ (subcutaneous tissue and fascia, trunk) and 0JWW0JZ (subcutaneous tissue and fascia, lower extremity).
The same procedure with a different approach is coded 0JWV3JZ (percutaneous) and 0JWVXJZ (external).
With a different device, use 0JWV00Z (drainage device), 0JWV03Z (infusion device), 0JWV07Z (autologous tissue substitute), 0JWV0HZ (contraceptive device), 0JWV0KZ (nonautologous tissue substitute), 0JWV0NZ (tissue expander) and 4 more.
It is a non-O.R. procedure that is part of the MS-DRG logic for DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), DRG 580 (Other Skin, Subcutaneous Tissue and Breast Procedures with CC) and DRG 581 (Other Skin, Subcutaneous Tissue and Breast Procedures without CC/MCC), under the surgical category “Other Skin, Subcutaneous Tissue and Breast Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- JSubcutaneous Tissue and Fascia
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- VSubcutaneous Tissue and Fascia, Upper Extremity
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
Different device
- 0JWV00ZDrainage Device
- 0JWV03ZInfusion Device
- 0JWV07ZAutologous Tissue Substitute
- 0JWV0HZContraceptive Device
- 0JWV0KZNonautologous Tissue Substitute
- 0JWV0NZTissue Expander
- 0JWV0VZInfusion Device, Pump
- 0JWV0WZVascular Access Device, Totally Implantable
- 0JWV0XZVascular Access Device, Tunneled
- 0JWV0YZOther Device
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Other Skin, Subcutaneous Tissue and Breast Procedures
ICD-9-CM equivalent
Converter →- 86.09Other incision of skin and subcutaneous tissueapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0JWV0JZ
Is 0JWV0JZ a valid ICD-10-PCS code for 2027?
- Yes. 0JWV0JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0JWV0JZ an O.R. procedure?
- No. 0JWV0JZ is designated non-O.R. in MS-DRG v44.0.
What DRG does 0JWV0JZ group to?
- Depending on the principal diagnosis, 0JWV0JZ can group to MS-DRG 579, MS-DRG 580 and MS-DRG 581.
What is the ICD-9 procedure code for 0JWV0JZ?
- The CMS GEMs map 0JWV0JZ to ICD-9-CM 86.09 (Other incision of skin and subcutaneous tissue).