ICD-10-PCS 2027 procedure code
0LPX4JZRemoval of Synthetic Substitute from Upper Tendon, Percutaneous Endoscopic Approach
Short description: Removal of Synth Sub from Up Tendon, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0LPX4JZ
0LPX4JZ is the ICD-10-PCS code for a removal procedure on the upper tendon using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, removal means taking out or off a device from a body part.
In plain terms, this corresponds to other tenotomy, the ICD-9-CM procedure title it maps to (83.13).
For a different body part, codes include 0LPY4JZ (lower tendon).
The same procedure with a different approach is coded 0LPX0JZ (open) and 0LPX3JZ (percutaneous).
With a different device, use 0LPX40Z (drainage device), 0LPX47Z (autologous tissue substitute), 0LPX4KZ (nonautologous tissue substitute) and 0LPX4YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 500 (Soft Tissue Procedures with MCC), DRG 501 (Soft Tissue Procedures with CC), DRG 502 (Soft Tissue Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Soft Tissue Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- LTendons
- 3. Operation
- PRemoval
Taking out or off a device from a body part
If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL
Includes: Drainage tube removal, cardiac pacemaker removal
- 4. Body Part
- XUpper Tendon
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Soft Tissue Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 83.13Other tenotomyapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0LPX4JZ
Is 0LPX4JZ a valid ICD-10-PCS code for 2027?
- Yes. 0LPX4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0LPX4JZ an O.R. procedure?
- Yes. 0LPX4JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0LPX4JZ group to?
- Depending on the principal diagnosis, 0LPX4JZ can group to MS-DRG 500, MS-DRG 501, MS-DRG 502, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0LPX4JZ?
- The CMS GEMs map 0LPX4JZ to ICD-9-CM 83.13 (Other tenotomy).