Skip to content
Dx

ICD-10-PCS 2027 procedure code

0LR70JZReplacement of Right Hand Tendon with Synthetic Substitute, Open Approach

✓ Valid for 2027O.R. procedure

Short description: Replacement of R Hand Tendon with Synth Sub, Open Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0LR70JZ

0LR70JZ is the ICD-10-PCS code for a replacement procedure on the right hand tendon using an open approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.

In plain terms, this corresponds to plastic operation on hand with other graft or implant, the ICD-9-CM procedure title it maps to (82.79).

For a different body part, codes include 0LR00JZ (head and neck tendon), 0LR10JZ (right shoulder tendon), 0LR20JZ (left shoulder tendon), 0LR30JZ (right upper arm tendon), 0LR40JZ (left upper arm tendon), 0LR50JZ (right lower arm and wrist tendon) and 21 more.

The same procedure with a different approach is coded 0LR74JZ (percutaneous endoscopic).

With a different device, use 0LR707Z (autologous tissue substitute) and 0LR70KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 040 (Peripheral, Cranial Nerve and Other Nervous System Procedures with MCC), DRG 041 (Peripheral, Cranial Nerve and Other Nervous System Procedures with CC or Peripheral Neurostimulator), DRG 042 (Peripheral, Cranial Nerve and Other Nervous System Procedures without CC/MCC), DRG 513 (Hand or Wrist Procedures, Except Major Thumb or Joint Procedures with CC/MCC), DRG 514 (Hand or Wrist Procedures, Except Major Thumb or Joint Procedures without CC/MCC) and DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), under the surgical categories “Peripheral, Cranial Nerve and Other Nervous System Procedures”, “Hand or Wrist Procedures, Except Major Thumb or Joint Procedures”, “Other Skin, Subcutaneous Tissue and Breast Procedures” and 2 more.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
LTendons
3. Operation
RReplacement

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure

Includes: Total hip replacement, bone graft, free skin graft

4. Body Part
7Hand Tendon, Right
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Hand or Wrist Procedures, Except Major Thumb or Joint Procedures

MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Hand Procedures for Injuries

ICD-9-CM equivalent

Converter →
  • 82.79Plastic operation on hand with other graft or implantapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0LR70JZ

Is 0LR70JZ a valid ICD-10-PCS code for 2027?

Yes. 0LR70JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0LR70JZ an O.R. procedure?

Yes. 0LR70JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0LR70JZ group to?

Depending on the principal diagnosis, 0LR70JZ can group to MS-DRG 040, MS-DRG 041, MS-DRG 042, MS-DRG 513, MS-DRG 514 and MS-DRG 579.

What is the ICD-9 procedure code for 0LR70JZ?

The CMS GEMs map 0LR70JZ to ICD-9-CM 82.79 (Plastic operation on hand with other graft or implant).