About 0NH003Z
0NH003Z is the ICD-10-PCS code for a insertion procedure on the skull using an open approach with infusion device. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.
The same procedure with a different approach is coded 0NH033Z (percutaneous) and 0NH043Z (percutaneous endoscopic).
With a different device, use 0NH004Z (internal fixation device), 0NH005Z (external fixation device), 0NH00MZ (bone growth stimulator) and 0NH00NZ (neurostimulator generator).
It is an operating-room procedure in the MS-DRG logic for DRG 023 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis with MCC or Antineoplastic Implant or Epilepsy with Neurostimulator), DRG 024 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis without MCC), DRG 025 (Craniotomy and Endovascular Intracranial Procedures with MCC), DRG 026 (Craniotomy and Endovascular Intracranial Procedures with CC), DRG 027 (Craniotomy and Endovascular Intracranial Procedures without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis”, “Craniotomy and endovascular intracranial procedures”, “Other O.R. Procedures for Injuries” and 1 more.
It was added in FY2022, effective October 1, 2021.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- NHead and Facial Bones
- 3. Operation
- HInsertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Includes: Insertion of radioactive implant, insertion of central venous catheter
- 4. Body Part
- 0Skull
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 3Infusion Device
Includes: Ascenda Intrathecal Catheter; InDura, intrathecal catheter (1P) (spinal); Non-tunneled central venous catheter; Peripherally inserted central catheter (PICC); Tunneled spinal (intrathecal) catheter
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy and endovascular intracranial procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Craniotomy for Multiple Significant Trauma
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2022 (effective 10/1/2021): Added
- No changes since FY2022.
Common questions about 0NH003Z
Is 0NH003Z a valid ICD-10-PCS code for 2027?
- Yes. 0NH003Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0NH003Z an O.R. procedure?
- Yes. 0NH003Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0NH003Z group to?
- Depending on the principal diagnosis, 0NH003Z can group to MS-DRG 023, MS-DRG 024, MS-DRG 025, MS-DRG 026, MS-DRG 027 and MS-DRG 907.