Skip to content
Dx

ICD-10-PCS 2027 procedure code

0PRM3JZReplacement of Right Carpal with Synthetic Substitute, Percutaneous Approach

✓ Valid for 2027O.R. procedure

Short description: Replacement of Right Carpal with Synth Sub, Perc Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0PRM3JZ

0PRM3JZ is the ICD-10-PCS code for a replacement procedure on the right carpal using a percutaneous approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.

In plain terms, this corresponds to other repair or plastic operations on bone, carpals and metacarpals, the ICD-9-CM procedure title it maps to (78.44).

For a different body part, codes include 0PR03JZ (sternum), 0PR13JZ (ribs, 1 to 2), 0PR23JZ (ribs, 3 or more), 0PR33JZ (cervical vertebra), 0PR43JZ (thoracic vertebra), 0PR53JZ (right scapula) and 20 more.

The same procedure with a different approach is coded 0PRM0JZ (open) and 0PRM4JZ (percutaneous endoscopic).

With a different device, use 0PRM37Z (autologous tissue substitute) and 0PRM3KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 513 (Hand or Wrist Procedures, Except Major Thumb or Joint Procedures with CC/MCC), DRG 514 (Hand or Wrist Procedures, Except Major Thumb or Joint Procedures without CC/MCC), DRG 906 (Hand Procedures for Injuries), DRG 957 (Other O.R. Procedures for Multiple Significant Trauma with MCC), DRG 958 (Other O.R. Procedures for Multiple Significant Trauma with CC) and DRG 959 (Other O.R. Procedures for Multiple Significant Trauma without CC/MCC), under the surgical categories “Hand or Wrist Procedures, Except Major Thumb or Joint Procedures”, “Hand Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
PUpper Bones
3. Operation
RReplacement

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure

Includes: Total hip replacement, bone graft, free skin graft

4. Body Part
MCarpal, Right
5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Hand or Wrist Procedures, Except Major Thumb or Joint Procedures

MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Hand Procedures for Injuries

ICD-9-CM equivalent

Converter →
  • 78.44Other repair or plastic operations on bone, carpals and metacarpalsapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0PRM3JZ

Is 0PRM3JZ a valid ICD-10-PCS code for 2027?

Yes. 0PRM3JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0PRM3JZ an O.R. procedure?

Yes. 0PRM3JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0PRM3JZ group to?

Depending on the principal diagnosis, 0PRM3JZ can group to MS-DRG 513, MS-DRG 514, MS-DRG 906, MS-DRG 957, MS-DRG 958 and MS-DRG 959.

What is the ICD-9 procedure code for 0PRM3JZ?

The CMS GEMs map 0PRM3JZ to ICD-9-CM 78.44 (Other repair or plastic operations on bone, carpals and metacarpals).