ICD-10-PCS 2027 procedure code
0PW307ZRevision of Autologous Tissue Substitute in Cervical Vertebra, Open Approach
Short description: Revision of Autol Sub in Cervcal Vertebra, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0PW307Z
0PW307Z is the ICD-10-PCS code for a revision procedure on the cervical vertebra using an open approach with autologous tissue substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of bone without division, other bones, the ICD-9-CM procedure title it maps to (77.19).
For a different body part, codes include 0PW007Z (sternum), 0PW107Z (ribs, 1 to 2), 0PW207Z (ribs, 3 or more), 0PW407Z (thoracic vertebra), 0PW507Z (right scapula), 0PW607Z (left scapula) and 20 more.
The same procedure with a different approach is coded 0PW337Z (percutaneous), 0PW347Z (percutaneous endoscopic) and 0PW3X7Z (external).
With a different device, use 0PW304Z (internal fixation device), 0PW30JZ (synthetic substitute) and 0PW30KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 495 (Local Excision and Removal of Internal Fixation Devices Except Hip and Femur with MCC), DRG 496 (Local Excision and Removal of Internal Fixation Devices Except Hip and Femur with CC) and DRG 497 (Local Excision and Removal of Internal Fixation Devices Except Hip and Femur without CC/MCC), under the surgical category “Local Excision and Removal of Internal Fixation Devices Except Hip and Femur”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- PUpper Bones
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 3Cervical Vertebra
Includes: Dens; Odontoid process; Spinous process; Transverse foramen; Transverse process; Vertebral arch; Vertebral body; Vertebral foramen; Vertebral lamina; Vertebral pedicle
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 7Autologous Tissue Substitute
Includes: Autograft; Cultured epidermal cell autograft; Epicel(R) cultured epidermal autograft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Local Excision and Removal of Internal Fixation Devices Except Hip and Femur
ICD-9-CM equivalent
Converter →- 77.19Other incision of bone without division, other bonesapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0PW307Z
Is 0PW307Z a valid ICD-10-PCS code for 2027?
- Yes. 0PW307Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0PW307Z an O.R. procedure?
- Yes. 0PW307Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0PW307Z group to?
- Depending on the principal diagnosis, 0PW307Z can group to MS-DRG 495, MS-DRG 496 and MS-DRG 497.
What is the ICD-9 procedure code for 0PW307Z?
- The CMS GEMs map 0PW307Z to ICD-9-CM 77.19 (Other incision of bone without division, other bones).