ICD-10-PCS 2027 procedure code
0PWS3JZRevision of Synthetic Substitute in Left Thumb Phalanx, Percutaneous Approach
Short description: Revision of Synth Sub in L Thumb Phalanx, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0PWS3JZ
0PWS3JZ is the ICD-10-PCS code for a revision procedure on the left thumb phalanx using a percutaneous approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of bone without division, other bones, the ICD-9-CM procedure title it maps to (77.19).
For a different body part, codes include 0PW03JZ (sternum), 0PW13JZ (ribs, 1 to 2), 0PW23JZ (ribs, 3 or more), 0PW33JZ (cervical vertebra), 0PW43JZ (thoracic vertebra), 0PW53JZ (right scapula) and 20 more.
The same procedure with a different approach is coded 0PWS0JZ (open), 0PWS4JZ (percutaneous endoscopic) and 0PWSXJZ (external).
With a different device, use 0PWS34Z (internal fixation device), 0PWS35Z (external fixation device), 0PWS37Z (autologous tissue substitute) and 0PWS3KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 495 (Local Excision and Removal of Internal Fixation Devices Except Hip and Femur with MCC), DRG 496 (Local Excision and Removal of Internal Fixation Devices Except Hip and Femur with CC) and DRG 497 (Local Excision and Removal of Internal Fixation Devices Except Hip and Femur without CC/MCC), under the surgical category “Local Excision and Removal of Internal Fixation Devices Except Hip and Femur”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- PUpper Bones
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- SThumb Phalanx, Left
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Local Excision and Removal of Internal Fixation Devices Except Hip and Femur
ICD-9-CM equivalent
Converter →- 77.19Other incision of bone without division, other bonesapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0PWS3JZ
Is 0PWS3JZ a valid ICD-10-PCS code for 2027?
- Yes. 0PWS3JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0PWS3JZ an O.R. procedure?
- Yes. 0PWS3JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0PWS3JZ group to?
- Depending on the principal diagnosis, 0PWS3JZ can group to MS-DRG 495, MS-DRG 496 and MS-DRG 497.
What is the ICD-9 procedure code for 0PWS3JZ?
- The CMS GEMs map 0PWS3JZ to ICD-9-CM 77.19 (Other incision of bone without division, other bones).