ICD-10-PCS 2027 procedure code
0RH40CZInsertion of Pedicle-Based Spinal Stabilization Device into Cervicothoracic Vertebral Joint, Open Approach
Short description: Insertion of Pedcl Stabl Dev into C-thor Jt, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0RH40CZ
0RH40CZ is the ICD-10-PCS code for a insertion procedure on the cervicothoracic vertebral joint using an open approach with spinal stabilization device, pedicle-based. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.
In plain terms, this corresponds to insertion or replacement of pedicle-based dynamic stabilization device(s), the ICD-9-CM procedure title it maps to (84.82).
For a different body part, codes include 0RH00CZ (occipital-cervical joint), 0RH10CZ (cervical vertebral joint), 0RH60CZ (thoracic vertebral joint) and 0RHA0CZ (thoracolumbar vertebral joint).
The same procedure with a different approach is coded 0RH43CZ (percutaneous) and 0RH44CZ (percutaneous endoscopic).
With a different device, use 0RH403Z (infusion device), 0RH404Z (internal fixation device), 0RH408Z (spacer), 0RH40BZ (spinal stabilization device, interspinous process) and 0RH40DZ (spinal stabilization device, facet replacement).
It is an operating-room procedure in the MS-DRG logic for DRG 028 (Spinal Procedures with MCC), DRG 029 (Spinal Procedures with CC or Spinal Neurostimulators), DRG 030 (Spinal Procedures without CC/MCC), DRG 518 (Back and Neck Procedures Except Spinal Fusion with MCC or Disc Device or Neurostimulator), DRG 907 (Other O.R. Procedures for Injuries with MCC) and DRG 908 (Other O.R. Procedures for Injuries with CC), under the surgical categories “Spinal Procedures”, “Back and Neck Procedures Except Spinal Fusion or Disc Device or Neurostimulator”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- RUpper Joints
- 3. Operation
- HInsertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Includes: Insertion of radioactive implant, insertion of central venous catheter
- 4. Body Part
- 4Cervicothoracic Vertebral Joint
Includes: Cervicothoracic facet joint
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- CSpinal Stabilization Device, Pedicle-Based
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Spinal Procedures
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Back and Neck Procedures Except Spinal Fusion or Disc Device or Neurostimulator
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 84.82Insertion or replacement of pedicle-based dynamic stabilization device(s)approximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0RH40CZ
Is 0RH40CZ a valid ICD-10-PCS code for 2027?
- Yes. 0RH40CZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0RH40CZ an O.R. procedure?
- Yes. 0RH40CZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0RH40CZ group to?
- Depending on the principal diagnosis, 0RH40CZ can group to MS-DRG 028, MS-DRG 029, MS-DRG 030, MS-DRG 518, MS-DRG 907 and MS-DRG 908.
What is the ICD-9 procedure code for 0RH40CZ?
- The CMS GEMs map 0RH40CZ to ICD-9-CM 84.82 (Insertion or replacement of pedicle-based dynamic stabilization device(s)).