ICD-10-PCS 2027 procedure code
0RW33JZRevision of Synthetic Substitute in Cervical Vertebral Disc, Percutaneous Approach
Short description: Revision of Synthetic Substitute in Cerv Disc, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0RW33JZ
0RW33JZ is the ICD-10-PCS code for a revision procedure on the cervical vertebral disc using a percutaneous approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to revision or replacement of artificial spinal disc prosthesis, cervical, the ICD-9-CM procedure title it maps to (84.66).
For a different body part, codes include 0RW03JZ (occipital-cervical joint), 0RW13JZ (cervical vertebral joint), 0RW43JZ (cervicothoracic vertebral joint), 0RW53JZ (cervicothoracic vertebral disc), 0RW63JZ (thoracic vertebral joint), 0RW93JZ (thoracic vertebral disc) and 22 more.
The same procedure with a different approach is coded 0RW30JZ (open), 0RW34JZ (percutaneous endoscopic) and 0RW3XJZ (external).
With a different device, use 0RW330Z (drainage device), 0RW333Z (infusion device), 0RW337Z (autologous tissue substitute) and 0RW33KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 028 (Spinal Procedures with MCC), DRG 029 (Spinal Procedures with CC or Spinal Neurostimulators), DRG 030 (Spinal Procedures without CC/MCC), DRG 518 (Back and Neck Procedures Except Spinal Fusion with MCC or Disc Device or Neurostimulator), DRG 519 (Back and Neck Procedures Except Spinal Fusion with CC) and DRG 520 (Back and Neck Procedures Except Spinal Fusion without CC/MCC), under the surgical categories “Spinal Procedures”, “Back and Neck Procedures Except Spinal Fusion or Disc Device or Neurostimulator”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- RUpper Joints
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 3Cervical Vertebral Disc
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 0RW03JZOccipital-cervical Joint
- 0RW13JZCervical Vertebral Joint
- 0RW43JZCervicothoracic Vertebral Joint
- 0RW53JZCervicothoracic Vertebral Disc
- 0RW63JZThoracic Vertebral Joint
- 0RW93JZThoracic Vertebral Disc
- 0RWA3JZThoracolumbar Vertebral Joint
- 0RWB3JZThoracolumbar Vertebral Disc
- 0RWC3JZTemporomandibular Joint, Right
- 0RWD3JZTemporomandibular Joint, Left
- 0RWE3JZSternoclavicular Joint, Right
- 0RWF3JZSternoclavicular Joint, Left
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Spinal Procedures
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Back and Neck Procedures Except Spinal Fusion or Disc Device or Neurostimulator
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 84.66Revision or replacement of artificial spinal disc prosthesis, cervicalapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0RW33JZ
Is 0RW33JZ a valid ICD-10-PCS code for 2027?
- Yes. 0RW33JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0RW33JZ an O.R. procedure?
- Yes. 0RW33JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0RW33JZ group to?
- Depending on the principal diagnosis, 0RW33JZ can group to MS-DRG 028, MS-DRG 029, MS-DRG 030, MS-DRG 518, MS-DRG 519 and MS-DRG 520.
What is the ICD-9 procedure code for 0RW33JZ?
- The CMS GEMs map 0RW33JZ to ICD-9-CM 84.66 (Revision or replacement of artificial spinal disc prosthesis, cervical).